143672 / 8295601300
2015-09-23·BA00·III·en·02
Maintenance and Repair
9
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Adaptors and reducers made of metal
Series 8295
8
Maintenance and Repair
8.1
Maintenance
• Consult the relevant national regulations to determine the type and extent of
inspections.
• Adapt inspection intervals to the operating conditions.
During maintenance of the device, check at least:
• Damage to seals and threads (Ex d II),
• compliance with the permissible temperatures (according to IEC/EN 60079-0),
• whether the device is used according to its designated use.
8.2
Maintenance
8.3
Repair
8.4
Returning the Device
Use the "Service form" to return the device if repair or service is required.
On the internet site "www.stahl-ex.com" under "Downloads > Customer service":
• Download the service form.
• Fill out the service form.
• Send the device along with the service form in the original packaging to
R. STAHL Schaltgeräte GmbH.
Observe the relevant national regulations in the country of use.
Replace the damaged components.