Operation, Installation and Maintenance Manual for 6414/11-Series
ID-No.:
240912 / 6414603300
Publication Code: 2015-04-30:BA00.lll.en.00 Page - 14 - of 17
WARNING
Using of the Cable glands and stopping plugs which are not approved.
The explosion protection is impaired!
Only use separately certified cable glands and stopping plugs.
Note:
the required dust resistance!
the required temperature resistance!
the required temperature resistance!
the IP degree of protection according to the rating plate!
the required tightening torques!
the operating instructions of the cable glands and stopping plugs!
the range of the permissible cable diameter!
8.
Commissioning
WARNING
Explosion hazard due to incorrect installation!
Non-compliance results in severe or fatal injuries.
Check the device before commissioning!
Explosion protection is impaired!
Comply with the National regulations.
Check the device for proper installation and function before commissioning.
Before commissioning, ensure that
the device has been installed according to regulations.
the power supply voltage and the rated operational voltage are identical.
the required cable diameter for cable glands has been used.
the cable entries and stopping plugs have been securely tightened.
the cables are correctly connected.
the connection has been performed correctly.
all screws and nuts are tightened according to regulations.
the connection chamber is clean.
the device is not damaged.
no foreign bodies are inside the device.
the device is sealed according to regulations.
NOTE
Condensation
due to specific environmental and operating conditions condensation cannot be avoided completely.
Operate the luminaire continuously or periodically over extended periods of time!
Avoid thermal bridges!