General

• Transport and store the device only in the original packaging.

• Store the device in a dry place (no condensation) and vibration-free.

• Do not drop the device.

6.2

Batteries

• Do not transport together with other materials.

• Do not transport in explosive dust atmosphere.

• Store protected from fire, sources of dust, harmful gases and liquids.

• Store in a dry and cool location.

Recommendation:

• Store battery at an ambient temperature of +5 to +25 °C and a relative humidity of  

65 ±5 %. The storage period is reduced of up to one month if stored outside this  

temperature range.

7

Mounting and installation

NOTICE

Risk of deep battery discharge due to exceeded storage!

Non-compliance can result in material damage!

• The battery should be charged within 26 weeks from date of production by means 

of operating the luminaire.

DANGER

Explosion hazard due to incorrect installation of the device! 

Non-compliance results in severe or fatal injuries.

• Carry out installation strictly according to the instructions and national 

safety and accident prevention regulations to maintain the explosion 

protection.

• Select and install the electrical device so that explosion protection is not 

affected due to external influences, i.e. pressure conditions, chemical, 

mechanical, thermal and electric impact such as vibration, humidity and 

corrosion (see IEC/EN 60079-14).

• The device must only be installed by trained qualified personnel who is 

familiar with the relevant standards.

Summary of Contents for 6148 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages r stahl com EN Portable Lamp Series 6148...

Page 2: ...se 6 3 3 Intended Use 6 3 4 Modifications and alterations 7 4 Function and device design 7 4 1 Function 7 4 2 Device design 7 5 Technical data 8 6 Transport and storage 10 6 1 General 10 6 2 Batteries...

Page 3: ...itional languages see r stahl com 1 4 Conformity with standards and regulations See certificates and EU Declaration of Conformity r stahl com The device has IECEx approval For certificate please refer...

Page 4: ...N EN EN EN EN EN EN EN EN Portable Lamp Series 6148 2 Explanation of the symbols 2 1 Symbols in these operating instructions Symbol Meaning Tips and recommendations on the use of the device General da...

Page 5: ...amage 2 3 Symbols on the device DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance with the instructio...

Page 6: ...ting instructions For assembly and installation Observe national assembly and installation regulations e g IEC EN 60079 14 Observe national safety and accident prevention regulations During installati...

Page 7: ...n with the charging unit To test the battery capacity 4 2 Device design DANGER Explosion hazard due to modifications and alterations to the device Non compliance results in severe or fatal injuries Do...

Page 8: ...C 4 years at 25 C LED 50 000 h at 50 C Luminous characteristics Lamps main light LED 3 W secondary light LED 0 5 W Light intensity 40 000 cd Light colour 6500 K Light distribution acc to DIN 14642 Fun...

Page 9: ...for 110 to 240 V AC 50 60 Hz A charging cable 12 to 30 V DC for vehicle operation is optionally available Charging current Charging time approx 11 h Function Charging starts when the portable lamp is...

Page 10: ...th if stored outside this temperature range 7 Mounting and installation NOTICE Risk of deep battery discharge due to exceeded storage Non compliance can result in material damage The battery should be...

Page 11: ...6148 7 1 Dimensions fastening dimensions Dimensional drawings All dimensions in mm inches Subject to alterations 14754E00 14753E00 Portable lamp Charging unit 14807E00 Drilling hole pattern for wall b...

Page 12: ...dous areas Non compliance results in severe or fatal injuries Only assemble and use the charging unit in safe areas The assembly site must be level and support the weight 14770E00 14771E00 Align the w...

Page 13: ...2 on a level surface 3 Secure it in the correct location using 3 screws 1 tightening torque 1 5 Nm screws are not included in delivery 21198E00 The connection cable supplied can be used to connect the...

Page 14: ...lt hook 14943E00 Insert the adaptor 1 into the third party charging unit LG443 2 Push the brackets 3 onto the third party charging unit LG 443 2 Fasten adaptor with the screws Torx 10 included in deli...

Page 15: ...ply voltage Ensure that the Power LED lights up Insert the portable lamp Portable lamp The LED display shows information on the charging state or possible faults DANGER Explosion hazard when used in h...

Page 16: ...ht flashes once per second The LED is switched off DANGER Explosion hazard due to incorrect installation Non compliance results in severe or fatal injuries Check the device for proper installation bef...

Page 17: ...t is placed in the charging unit it switches off any LEDs that are switched on performs a function test and indicates the state of charge and any errors via the LED display In case of power failure th...

Page 18: ...Emergency light mode function is on With the function switched off and in case of power failure the following states will be activated at the portable lamp red green green green green Description Eme...

Page 19: ...nction switched on 9 3 2 Charging switch off when used in a motor vehicle Activating and deactivating Switch on the secondary light Press button again and keep it pressed Press and hold the button whi...

Page 20: ...e LED display Start battery test Keep pressing the button until the LED display shows the battery test The LEDs of the LED display are switched on and off one after the other DANGER Explosion hazard w...

Page 21: ...tely filled LED lights up Field half full LED blinking Field empty LED off Battery capacity Dimming mode red green green green green Description Battery test aborted Interruption of the charging opera...

Page 22: ...pacity 98 Battery capacity 98 red green green green green Description Emergency lighting function off Emergency lighting function on red green green green green Description Charging switch off off Cha...

Page 23: ...ement Disconnect and then reconnect battery Close the portable lamp Insert portable lamp into charging unit Charge battery If the error cannot be eliminated using the mentioned procedures Contact R ST...

Page 24: ...r the device enclosure and or protective enclosure has have cracks or other visible signs of damage Compliance with the permissible temperatures according to EN 60079 Whether the device is used as int...

Page 25: ...crew down the battery retaining bracket with the screws 3 tightening torque 0 5 Nm DANGER Explosion hazard if the device is opened in a hazardous area Non compliance results in severe or fatal injurie...

Page 26: ...Contact the responsible representative from R STAHL R STAHL s customer service is available to handle returns if repair or service is required Contact customer service personally or Go to the r stahl...

Page 27: ...e surrounding environment is contaminated Non compliance can result in minor injuries and environmental damage Batteries collect them separately dispose of them in controlled fashion do not dispose of...

Page 28: ......

Reviews: