Floodlight LED

Series 6125

2

Explanation of the symbols

2.1

Symbols in these operating instructions

2.2

Warning notes

Warnings must be observed under all circumstances, in order to minimize the risk due to 

construction and operation. The warning notes have the following structure:

• Signalling word: DANGER, WARNING, CAUTION, NOTICE

• Type and source of danger/damage

• Consequences of danger

• Taking countermeasures to avoid the danger or damage

Symbol

Meaning

Tips and recommendations on the use of the device

Danger due to explosive atmosphere

Danger due to live components

Risk of damage to the eyes caused by optical radiation

DANGER

Danger to persons

Non-compliance with the instruction results in severe or fatal injuries to  

persons.

WARNING

Danger to persons

Non-compliance with the instruction can result in severe or fatal injuries to 

persons.

CAUTION

Danger to persons

Non-compliance with the instruction can result in light injuries to persons.

NOTICE

Avoiding material damage

Non-compliance with the instruction can result in material damage to the device and / or 

its environment.

Summary of Contents for 6125 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages r stahl com EN Floodlight LED Series 6125...

Page 2: ...2 3 Symbols on the device 5 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Intended Use 6 3 4 Modifications and alterations 6 4 Function and device design 6 4 1 Function 6 4...

Page 3: ...ee r stahl com 1 4 Conformity with standards and regulations See certificates and EU Declaration of Conformity r stahl com The device has IECEx approval For certificate please refer to the IECEx homep...

Page 4: ...quences of danger Taking countermeasures to avoid the danger or damage Symbol Meaning Tips and recommendations on the use of the device Danger due to explosive atmosphere Danger due to live components...

Page 5: ...ical data We cannot be held liable for damage to the device caused by incorrect or unauthorised use or non compliance with these operating instructions For assembly and installation Observe national a...

Page 6: ...equipment used for lighting areas work equipment and objects It can be used indoors and outdoors The floodlight is certified for use in Zones 1 2 21 and 22 hazardous areas DANGER Explosion hazard due...

Page 7: ...N EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Floodlight LED Series 6125 4 2 Device design 17562E00 1 Cable glands 6 Seal 2 Mounting bracket 7 Luminaire glass cover 3 Connection terminal...

Page 8: ...Certificates IECEx ATEX EAC TR CU India PESO Technical Data Electrical data Control gear Rated voltage AC 220 to 240 V 10 50 to 60 Hz Rated current Inrush current Power factor 0 95 THD 10 Power at amb...

Page 9: ...e at 60 C provided the luminaire is switched on at 40 C Delay of 10 seconds below 40 C during cold start Storage temperature 40 to 75 C Technical Data 6125 11 2 6125 11 4 Power consumption W 120 210 C...

Page 10: ...ng Installation Cable entry 1 x cable glands Series 8161 1 x stopping plugs Series 8290 Connection Through wiring max 12 A Technical Data Ta 40 C Ta at 45 C Ta at 50 C Ta at 55 C Ta at 60 C L70B10C10...

Page 11: ...f the device Non compliance results in severe or fatal injuries Carry out installation strictly according to the instructions and national safety and accident prevention regulations to maintain the ex...

Page 12: ...s all dimensions in mm inches Subject to modification 18200E00 18201E00 Floodlights with cooling element Version 210 W Floodlights without cooling element Version 120 W 17561E00 Mounting bracket 400 1...

Page 13: ...s in severe or fatal injuries Avoid external heat sources and or direct sunlight risk of change of temperature class or change of maximum permissible surface temperature Do not exceed the maximum ambi...

Page 14: ...uries Open luminaires without switch only in de energized state see information plate on the lock NOTICE Danger due to electrostatic discharge Electronic components can be destroyed if touched Do not...

Page 15: ...o not mix up the conductors Observe the technical regulations when connecting the conductor Clamp the conductor firmly Connection terminals Through wiring of the mains supply connection Standard Sprin...

Page 16: ...d type of protection the required temperature resistance the IP degree of protection according to the rating plate the operating instructions of the cable entries and stopping plugs the required tight...

Page 17: ...ened firmly Check if all conductors have been clamped firmly Check if the line voltage and the rated operational voltage are consistent Check if the permissible conductor diameter for the correspondin...

Page 18: ...n inside and out Whether the permissible temperatures in accordance with EN 60079 are complied with DANGER Explosion hazard due to hot built in components Non compliance results in severe or fatal inj...

Page 19: ...e is required Contact customer service personally or Go to the r stahl com website Under Support RMA select RMA REQUEST Fill out the form and send it You will automatically receive an RMA form via ema...

Page 20: ...use aggressive detergents or solvents 11 Disposal Observe national and local regulations and statutory regulation regarding disposal Separate materials when sending it for recycling Ensure environmen...

Page 21: ......

Reviews: