GRP combination signal – 110 db(A)/
5 joules, flameproof
Series YL6S
7.3.3 Configuration
• For signal tone selection and its switch positions, refer to the table below.
• Check whether the switch positions are correct for the selected signal tones
Details of sound selection switch
Audible settings
Recommendation
• The signal tone selection should be set at the factory or at an approved
factory.
Do not use tone 12, 14 and 32 for AC variants.
17192E00
Sou-
nd
no.
SW1/SW2
Frequency
Repetition rate
Sound description Special
application
SW
x.1
SW
x.2
SW
x.3
SW
x.4
SW
x.5
01
0
0
0
0
0
500 to 1200 Hz
3 s
Siren
02
1
0
0
0
0
1200 to 500 Hz
1 s
Reverse sweep
Fire alarm,
Germany
(DIN 33404)
03
0
1
0
0
0
500 to 1200 Hz
4.5 s
Slow wailing
sound
Evacuation,
Netherlands
04
1
1
0
0
0
500 to 1000 Hz
0.15 s
Fast wailing sound
05
0
0
1
0
0
800 to 1000 Hz
As standard
ISO 8201
Evacuation
International
evacuation alarm
06
1
0
1
0
0
1000 Hz
10/40/10 s
Constant rise and
fall
TELEPHONE
INITIATE
NEUTRAL
NEUTR
0V
LIVE (Vac)
24/48 Vdc
2ND
STAGE
3RD
STAGE
STROBE
AC/DC
1
2