GRP combination signal – 110 db(A)/
5 joules, flameproof
Series YL6S
• Mount the device on a flat surface suitable for its weight.
• Direct the tone output towards the area to be covered.
• Insert the electrical lines using a certified and flameproof cable entry which is suitable
for the gas group.
• Close unused entries using certified, flameproof stopping plugs.
7.3
Installation
The electrical installation and configuration of the device is performed in the following
sequence:
• Dismounting the device (see chapter 7.3.1)
• Electrical connections (see chapter 7.3.2)
• Configuration (see chapter 7.3.3)
• Mounting the device (see chapter 7.3.4)
• Mounting the earth connection (see chapter 7.3.5)
• Adjusting the volume (see chapter 7.3.6)
7.3.1 Dismounting the device
17161E00
• Fix the bracket to the wall.
17162E00
• Mount the device.