To invert the opening direction of the arm, move the spring to the opposite position (Fig.8)
and invert the connection of the electric motor to the control panel (Fig.9).
8
APM1
9
CHM1
10
LAMP
11
LAMP
12
LC
13
LC
24V 120W
M1
Fig.8
Fig. 9
•
Balance the barrier’s arm adjusting the screwable rods. The arm must be in equilibrium in
the half way position (45°).
45°
•
Proceed with the programming of the control panel following the specific electrical
instructions and then regulate the position of the arm’s limit switches, lowering or raising
the relative rubber antivibration drums