Preliminary check
Before installing the motor, check the topics below:
•
Gate structure must be tough and there must not be any friction between the wing and
its pivot;
•
Gate pivots must work correctly and be lubricated enough;
•
There must be a closing limit stop to avoid to overrun of the wing (if a mechanical stop is
not used).
Brackets fixing on the column and on the gate (drowning 1 and drowning 2)
Once you checked that the motor can be installed, fix the bracket plate on the column 100mm
far from the ground (use
∅
14 rawlplung and M8 screws); fix now the bracket plate on the wing
(use M6 screws), following the quotes in the table
1 (if mechanical stops are not used) or in
the table 2 (if mechanical stops are used).