Calibrating the microswitches (Alpheo 230V) with the geared motor installed on the left
Opening:
With the geared motor released, open the gate to the point wanted; turn the lower cam
clockwise until the lower microswitch trips and then lock it with the relative screw.
Lower microswitch
Lower Cam
Fixing Screw
Lower Cam
Closing:
With the geared motor released, close the gate and turn the top cam counter clockwise until
the microswitch trips and then lock it with the relative screw.
Upper Microswitch
Upper cam
Fixing Screw