Fixing and adjustment of mechanical stops for limit switches
If you want to use mechanical stops, they must be put on their own tracks on the lower part of the Alpheo
motor. To adjust the stops, close the gate and slide the mechanical stop 1 until it is next to the motor arm.
Fix now the stop using a hexagonal M8x30 screw (wrench N°13). To use the mechanical stop even in the
opening phase, repeat the same operation on the mechanical stop 2 as described on the drowning below.
Adjustment of the mechanical stop 1 closing phase.
Adjustment of the mechanical stop 2 in opening phase.
The drowning is referred to the opening and closing phase of the left wing. For the right one, the position
of the two mechanical stops is inverted.
MECHANICAL
STOP 1
MECHANICAL
STOP 2
MECHANICAL
STOP 1
MECHANICAL
STOP 2
Summary of Contents for ALPHEO 230V