Power 

connection

 

The equipment has an auto-switching power supply that can accommodate a 
wide range of input voltages. The only thing necessary to do before powering on 
the unit is to make sure the line voltage you are applying is within the range of 
accepted voltages. This equipment will accommodate between 100V and 240v 
AC 50-60HZ. It is possible to daisy chain the power connection from one fixture 
to the next. We recommend not connecting more than 30 fixtures on one 16A 
220V socket and not more than 15 fixtures on one 16A 110V socket. 
 

Color 

Connection 

PIN 

Brown 

AC live wire 

Blue 

AC zero curve 

Green/Yellow 

AC ground wire 

 

 

DMX Serial Data Link

 

1. Connect the male 3pin DMX input of the first fixture to the female 3pin DMX 
output of the lighting controller using 110 Ohm DMX cable, for example a Stagg 
Commandor 10 (skip this step when not using a controller) 
2. Connect the output of the first fixture to the input of the next fixture using 110 
Ohm DMX cable. Repeat this process until you reach your last fixture. Here it is 
recommended to connect a DMX terminator to the output of the last fixture in the 
chain.  
 

 

 

 

 

 

 

Summary of Contents for ECOPAR2

Page 1: ...User Manual ECOPAR2 SLI ECOPAR2...

Page 2: ...s 1 BEFORE USAGE This package contains Unpacking Introduction Specifications Features 2 INSTALLATION Power Connection DMX 512 Connection 3 OPERATION Control panel Function Menu Map Operating Instructi...

Page 3: ...ct your vendor or our customer support number for further instructions Introduction This fixture can operate in six different operating modes DMX control sound active automatic manual setup infrared r...

Page 4: ...improvements in the design of this unit and this manual are subject to change without any prior written notice 2 INSTALLATION Installation requirements The product can be hung or placed on a solid su...

Page 5: ...tures on one 16A 220V socket and not more than 15 fixtures on one 16A 110V socket Color Connection PIN Brown AC live wire 1 Blue AC zero curve 2 Green Yellow AC ground wire 3 DMX Serial Data Link 1 Co...

Page 6: ...3 OPERATION Menu Map...

Page 7: ...lect a preset color press ENTER to confirm Select AtF and press ENTER to enter AtF mode which lets you mix your own color Enter the desired amount of Red into rxxx press ENTER the desired amount of Gr...

Page 8: ...layed then press ENTER Sla will now be displayed Slave mode is selected for this fixture it will follow automatic programs sound mode and fixed color atf selection of the Master fixture it is connecte...

Page 9: ...e two Sound Controlled Programs You can adjust the sensitivity of the microphone with the SPEED button explained below 6 SPEED When the fixture is in AUTO mode this button will adjust the speed of the...

Page 10: ...annel modes this will allow you to create custom lightshows Follow the instruction on the following DMX address charts DMX Channels 1 Channel Mode Channel Value Function 1 0 15 16 31 32 47 48 63 64 79...

Page 11: ...rs 2 0 255 Dimmer 0 100 3 Channel mode Channel Value Function 1 0 255 COLOR MACROS See 1 Channel DMX mode for colors 2 0 255 Dimmer 0 100 3 0 15 16 255 Strobe OFF STROBE 0 20Hz 4 Channel mode Channel...

Page 12: ...0 4 0 255 White 0 100 5 0 255 Dimmer 0 100 6 Channel mode Channel Value Function 1 0 255 Red 0 100 2 0 255 Green 0 100 3 0 255 Blue 0 100 4 0 255 White 0 100 5 0 255 Dimmer 0 100 6 0 255 COLOR MACROS...

Page 13: ...hannel DMX mode for colors 8 Channel mode Channel Value Function 1 0 255 Red 0 100 2 0 255 Green 0 100 3 0 255 Blue 0 100 4 0 255 White 0 100 5 0 255 Dimmer 0 100 6 0 15 16 255 0 255 0 31 32 255 OFF S...

Page 14: ...TIVE MODE SOUND ACTIVE MODE 1 SOUND ACTIVE MODE 2 When Channel 7 is at a value of 0 51 Channels 1 4 are used and Channel 6 will control strobe When Channel 7 is at a value of 52 102 Channel 8 is in Co...

Page 15: ......

Page 16: ...rom the mains outlet and switch off the mixer immediately MARKING CONFORMITY 1 The CE mark on this product means it conforms to the EMC Directive 2004 108 CE CE marking Directive 93 68 EEC and Low Vol...

Reviews: