10
Manual Fogging Operation ..............................................................
1. As long as heating is completed, turn on the “ Manual fog”
button, the machine with maximum output fogging;
2. Turn off the “Manual fog” button to stop.
3. When the machine stops fogging, please do not unplug the
machine immediately, but wait 100 seconds to let the machine
automatically clean the fluid left in the pipe. This is to avoid causing
negative effect when used next time.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a
solution is found. Once the unit operates properly, do not carry out
following steps. If the problem persists, refer servicing to a qualified
technician.
Power Connected but No Smoke is Emitted:
1. Check the power supply. Plug the unit into grounded electric
power supply socket with proper voltage.
2. Disconnect the machine from electric power supply. Replace fuse
with one of the same type.
3. Keep sufficient fluid in tank.
4. Check if the oil pipe has normal fluid pumping.
5. Check if the oil pipe is broken.
6. Check if pump is working (with fluid flow or not).
7. Check if the heater is heating (touch the panel to see if it is warming).
8. Check your controller if in correct connection.