Programming 

The firing segment 

The ST312A firing segment comprises 2 ramps followed by a soak period.  
This single segment can be used for simple firing (biscuit firing for exam-
ple). 
 
The ST312A ramps the kiln temperature at ramp rate 1 until the kiln 
reaches temperature t1.  It then ramps the kiln temperature to the soak 
temperature at ramp rate 2.  It then soaks (dwells) at the soak temperature 
for the soak time.  It then allows the kiln to cool naturally. 
 
The ST312A is capable of both positive (heating) ramps and negative 
(cooling) ramps - as used in glassmaking for annealing. 
 
Ramp rate 1 & ramp rate 2 are settable in the range 1°C/hour to 999°C/
hour or 

FULL 

(full power) or 

End 

(end of program). 

 
t1 & the soak temperature are settable over the range 0 to 1320°C. 
 
The soak time is settable over the range 00.00 (no soak) to 99 hours 59 
mins. 

Note: during soaking the ST312A display alternates every 5 seconds 
between kiln temperature and soak time remaining. 

Pr

ogramming 

t1 

soak temperature 

ra

mp

 ra

te 

ra

m

ra

te

 2

 

soak period 

ST312A User Handbook 

 

 

 

 

       Page   15 

Program Pause Facility 

While firing press and hold down the  

ª

 key for about 4 seconds.  The 

ST312A will pause the executing program.  To un-pause the program 
press and hold down the 

ª

 key again for about 4 seconds.  The effects of 

pausing are as follows:- 
 
If paused during a ramp the kiln temperature will be held (soaked) 

indefi-

nitely

 at the current kiln temperature.  The ramp will continue when un-

pause is selected. 
 
If paused during a soak then the soak time will be 

extended indefinitely

.  

The remainder of the soak period will be resumed when un-pause is se-
lected. 
 
Segment advance (

©

 key held down for about 4 seconds) can also be used 

to terminate the pause.  This will advance the segment and will immedi-
ately terminate a paused soak and end the firing program. 
 
Changes made to the operation of the ST312A in this way are temporary 
and are not stored. 

 PAUSED

 

 600

 

°C 

°C/hr 

hr.min 

As a warning during pause a double 
beep is sounded every 10 seconds, 
the display scrolls 

PAUSed

 for 5 

seconds then shows the kiln tem-
perature for 5 seconds. 

Adjusting While 

Firing 

WARNING - PROGRAM PAUSE 
The program pause facility should be used with care.  Program execution is 
suspended and the kiln will be held at its current temperature indefinitely.   
 
If left too long at high temperatures kiln damage could result. 

Summary of Contents for ST312A

Page 1: ...df ST312A User Handbook Page 1 ST312A User Handbook ST312A Temperature Programmer TAFFOR S D Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www staffordinstruments co uk email support stafford inst co uk Issue 2 00 Date 01 June 2009 See separate handbook for User Instructions Copyright 2009 Stafford Instruments Ltd ...

Page 2: ...0 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enamel 90 C hr 600 C 00 30 Heavy Sculpture 50 C hr 300 C 00 30 Lustre 90 C hr 600 C 00 00 Ramp 2 FULL FULL FULL FULL FULL FULL FULL FULL 70 C hr FULL Soak temp 960 C 1000 C 1160 C 960 C 1040 C 1140 C 1250 C 780 C 1000 C 750 C Sample Programs...

Page 3: ...t locked Press and hold in both the ª keys for 5 seconds to lock the ST312A Power Failure Recovery If power fails during firing then the ST312A recovers as follows For power failure during start delay the ST312A commences firing immedi ately when power returns For power failure during ramp 1 or ramp 2 the ST312A goes back into the ramp it was previously executing For power failure during soaking t...

Page 4: ... to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312A turn off the power to the instrument and have the fault investigated by your installer or kiln service engineer to rectify the fault Technical note any error message will cause the auxiliary alarm relay if fitted to open see installation handbook for details Note these error...

Page 5: ...hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312A User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8 8 When turned on the ST312A performs a display test by briefly illuminating all of the display digits and all of the front panel lamps The version number of the software embedded within the ST312A is n...

Page 6: ...ogram Pause Facility While firing press and hold down the ª key for about 4 seconds The ST312A will pause the executing program To un pause the program press and hold down the ª key again for about 4 seconds The effects of pausing are as follows If paused during a ramp the kiln temperature will be held soaked indefi nitely at the current kiln temperature The ramp will continue when un pause is sel...

Page 7: ...re If currently soaking then the ST312A will end the firing Changes made to the operation of the ST312A in this way are temporary and are not stored Adjusting While Firing ST312A User Handbook Page 7 When the ST312A is not firing there are no lamps lit on the mimic panel the run lamp is off and the display shows the kiln temperature with the C indicator lit Altering the program 20 C C hr hr min If...

Page 8: ...se through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to obtain the required ramp rate in the range 1 C hr to 999 C hr If full power is required then push the key until FULL is diplayed ST312A User Handbook Page 13 Cooling Upon completion of firing the ST3...

Page 9: ...feature can be disabled see installation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312A is turned on ST312A User Handbook Page 9 Firing To start a firing press the START STOP key The RUN lamp will light To stop the firing prematurely press the START STOP key again 20 C C hr hr min If the left hand decimal point is on then the keyboard is locked the ST31...

Page 10: ...Page ST312A User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312A User Handbook Page 11 Program Description Please photocopy me ...