Summary of Contents for ST312

Page 1: ...ser Handbook Page 1 ST312 User Handbook STAFFOR D INSTRUMENTS Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www stafford inst co uk email support stafford inst co uk Issue 1 002 D...

Page 2: ...Low Temperature Glaze 90 C hr 600 C 00 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enam...

Page 3: ...not locked Press and hold in both the keys for 5 seconds to lock the ST312 Power Failure Recovery If power fails during firing then the ST312 recovers as follows For power failure during start delay t...

Page 4: ...312 to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312 turn off the power to the instrument and have the fault investigated by y...

Page 5: ...99 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312 User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8...

Page 6: ...am Pause Facility While firing press and hold down the key for about 4 seconds The ST312 will pause the executing program To un pause the program press and hold down the the key again for about 4 seco...

Page 7: ...rature If currently soaking then the ST312 will end the firing Changes made to the operation of the ST312 in this way are temporary and are not stored Adjusting While Firing ST312 User Handbook Page 7...

Page 8: ...through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to ob...

Page 9: ...ture can be disabled see in stallation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312 is turned on ST312 User Handbook Page 9 Firing To start a firing press...

Page 10: ...Page ST312 User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312 User Handbook Page 11 Program Description Please photocopy me...