System Maintenance
Hydraulic
Fluid:
Drain and replace hydraulic oil every 6 to 12 months depending on use.
Recommended Fluid: Mobil DTE 10-32 or equivalent.
Filter:
Remove 3 cap screws on top of filter housing.
Remove filter cartridge and spring.
Replace with new filter cartridge and spring Part Number 934331.
Apply anti-seize to cap screws and tighten.
Pump:
Inspect periodically for leaks.
Check hoses for signs of wear.
Motor:
Inspect periodically for leaks.
Check hoses for signs of wear.
PTO
Grease output shaft every 6 to 12 months depending on use.
If PTO does not have a grease zerk on output shaft, remove direct mount
hydraulic pump and grease the output shaft using a high quality gear lube.