DIAGRAM C
Filter assembly procedures for THERMAFLOW Model 500P
INSTALLATION GUIDE, OPERATING PROCEDURES & PARTS BREAKDOWN
PAGE 6
STAC INC
ST PAUL MN
800-334-7699
STEP 5 Final Assembly
A) Complete all hydraulic and product plumbing.
B) Fill the reservoir until the oil level gets to the top black line on the site level gauge.
NOTE: After the initial start up procedure you will need to add oil due to the hydraulic
lines filling up to capacity.
NOTE: Over-filling the reservoir will cause the oil to expand up through the breather
assembly when the oil warms up.
NOTE: We recommend using a high grade of hydraulic oil with a Pour Point of -50°F.
This will ensure proper oil flow during extreme cold weather operation. Use of synthetic
hydraulic oils is also recommended. Recommended Oil: MOBIL DTE 10-32 or
equivalent.