STEP 1 POSITIONING & MOUNTING
The Model 500P is required to be mounted in a position that meets the DOT’s requirements
for roll-over-protection. See diagram below for proper mounting bracket and shock mount
installation.
NOTE: The THERMAFLOW Model 500P can be mounted either from the rear
or bottom mounting holes.
NOTE: Please contact your local DOT representative if you have any
questions concerning the DOT’s requirements on mounting of equipment that
require roll-over-protection.
NOTE: STAC, INC. does not assume any liability for its products if they are
mounted or plumbed in a way that does not meet the DOT’s requirements.
STEP 2 INSTALLING THE PTO & HYDRAULIC PUMP
A) Install the PTO to the transmission and mount the hydraulic pump according to
the instructions included with the PTO.
HELPFUL HINT
:
If you are using a direct mount hydraulic pump/PTO combination,
be sure that the pump splines are well lubricated with a heavy grease. This grease will
prevent premature spline wear on the PTO and pump shafts. A small packet of this
grease is available through STAC, INC. P/N 300980.
INSTALLATION GUIDE, OPERATING PROCEDURES & PARTS BREAKDOWN
PAGE 3
STAC INC
ST PAUL MN
800-334-7699
IN MOUNTING
KIT 500550
IN MOUNTING
KIT 500550
IN MOUNTING
KIT 500550
IN MOUNTING
KIT 500550
500200
500200
500032
THE 500P CAN BE MOUNTED
USING METHOD A OR B
METHOD A
METHOD B
MOUNTING BRACKET
500130
®