Mounting and commissioning
If you want to lock the smoke alarm device on the mounting afterwards,
remove the fixing pin now (e.g. by means of a screw driver).
Mark the position for the drilling holes
at the mounting position by using the
mounting as a drilling jig.
Drill the appropriate two holes for the fixing screws (please use the
enclosed dowels for an installation on a masonry or gypsum subsurface)
and screw down the mounting.
Note:
Make a note of the date of first activation, the device must be
replaced no later than 10 years after commissioning! This replacement
date may be later than the recommended date of replacement indicated
on the nameplate.
Turn the smoke alarm device clockwise on the mounting, until it locks
in.
Important: The smoke alarm device has to be activated now!
Press the test button for approx. 5 seconds until the red LED flashes
shortly. When the button is released, an alarm tone will sound.
Wait approx. 40 seconds until the red LED flashes again. The smoke
detector is now ready for operation.
If required you can now additionally lock the smoke alarm device on the mounting
by sticking the fixing pin into the small opening.
Function test
After having installed the smoke alarm device, you should necessarily perform a function test!
Do not expose your ears directly to the alarm signal, but hold the device at arms length. Press the test
button (large round button in the middle) for approx. 5 sec. until the alarm signal sounds and the LED
flashes rapidly.
The device must be tested at least once a year (see type plate and instructions). In the meantime, however,
contamination of the sensor chamber by dust may impair the function of the smoke detector. The openings
in the housing should be vacuumed at least once a month. We recommend frequent testing of the device.
LED indicators und alarm tones
Operating status
LED
Acoustic signal
Readiness for operation slowly flashing (every 40 sec.)
-
Test function
rapidly flashing
loud beeps in rapid sequence
Alarm triggering
rapidly flashing
loud beeps in rapid sequence
Alarm muting
flashes every 8 sec.
-
Battery-low-warning
slowly flashing (every 40 sec.)
beep every 40 sec.
Malfunction indicator
slowly flashing (every 40 sec.)
beep every 40 sec.
holes
in the ceiling
plastic
dowels
mounting
screws
housing
8