Piping:

Use at least 1-1/2" (38mm) pipe with 5” (127mm) trap. Use 2” (51mm) pipe
with 6” (152mm) trap. Increase size if a long run is needed. 
To avoid strains on the pump, support both suction and discharge pipes inde-
pendently. Place these supports near the pump.
To avoid a strain left by a gap at the last connection, start all piping at the
pump and run pipe away from the pump.
Never use a suction pipe smaller than pump suction connection. To avoid air-
locking, slope suction pipe slightly upward toward the pump.
NOTICE: To prevent flooding when removing pump for service, all flooded
suction systems must have gate valves in suction and discharge pipes.

Fittings:

Fittings restrict flow; for best efficiency use fewest possible fittings.
Avoid fittings which could cause an air trap.
Pool fittings must conform to International Association of Plumbing and
Mechanical Officials (IAPMO) standards.
Use only non-entrapping suction fitting or double suction.

TABLE I - RECOMMENDED FUSING AND WIRING DATA

Serv. to Motor - Dist. in Ft. (M)

Motor

Branch Fuse

Max Load

Voltage/

0-100'

101-200'

201-300'

HP

Rating Amps*

Amps

Hz/Phase

(0-30)

(30-60)

(60-90)

PE5YD-133L

3/4-1/8

15

12.0/4.0

115/60/1

14(2)

14(2)

12(3)

PEXYD-133L

PEAXYE-133L

1-1/6

15

12.0/4.0

115/60/1

14(2)

14(2)

12(3)

PEAXYE-124L

1-1/6

15

5.3/2.0

230/60/1

14(2)

14(2)

14(2)

PEAXYG-126L

2-1/3

15

10.1/3.7

230/60/1

14(2)

14(2)

12(3)

PEAXYG-126LS

2-1/3

15

10.1/3.7

230/60/1

14(2)

14(2)

12(3)

* Time delay fuses are recommended instead of standard fuses in any motor circuit.

AWG

Wire

Size

(mm

2

)

}

L2

B

A

L1

Lo

Hi

Timer Motor

Supply

Lo

Hi

Circuit

Protector

Remote

SPDT

Switch

Ground

(Green)

Common

Remote Switching For 2-Speed Pumps

Timer (optional)
Low Speed Only

Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.

Summary of Contents for PE5YD-133L

Page 1: ...ta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Union City TN Delavan WI M...

Page 2: ...ULLY The Sta Rite PE and PEA Series Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety I...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Page 4: ...to pump with union half use Teflon tape or Plasto Joint Stik between pipe and union adapter Union collar to pump should be assembled dry and hand tight NOTICE Pump suction and discharge connections h...

Page 5: ...conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to...

Page 6: ...e required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG 8 4 sq mm or larger Run wire from external bonding...

Page 7: ...er fill trap and pump with water Lubricate trap cover O Ring with petroleum jelly each time it is removed Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to...

Page 8: ...d by hand 3 Cap inlet piping after draining to keep water out of the pipes 4 To prevent pump from freezing remove the trap cover and drain the tank body through the two drain plugs provided Clean pump...

Page 9: ...ure in trap body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulle...

Page 10: ...l in seal plate NOTICE On 2 HP models install impeller screw left hand thread turn counterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble mo...

Page 11: ...er is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8 Impeller and diffuser...

Page 12: ...12 1 2 3 4 19 20 8 5 6 9 10 11 14 15 16 12 13 17 18 7 21 2243 0196 PE and PEA Series MAX E GLAS 2 Speed Pool Pump 3 4 1 and 2 HP Models...

Page 13: ...s U27 67 Tag CAUTION This pump equipped C63 13 with mech shaft seal Tag CAUTION Securely tighten and C63 10 center trap cover prior to pressure testing Nameplate U33 121 Not illustrated Models PEAXYG...

Page 14: ...haul Kits HP Parts Pak Number 3 4 PP1014 1 PP1016 Kit includes Impeller Diffuser Shaft Seal Gaskets O Rings Hardware Shims Wear Rings and Inserts Seal Gasket Kit Kit includes Shaft Seal Gaskets and O...

Page 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Page 16: ...16...