ELECTRICAL

Ground motor before connecting to electrical power supply. Failure to

ground motor can cause severe or fatal electrical shock hazard.

Do not ground to a gas supply line.

To avoid dangerous or fatal electrical shock, turn OFF power to motor

before working on electrical connections.

Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical

problem. If GFCI trips and will not reset, have a qualified electrician

inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage. Incorrect voltage

can cause fire or seriously damage motor and voids warranty. If in

doubt consult a licensed electrician.

Voltage

Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power company.

Grounding/Bonding

Install, ground, bond and wire motor according to local or National Electrical
Code requirements.
Permanently ground motor. Use green ground terminal provided under motor
canopy or access plate (See Fig. 2); use size and type wire required by code.
Connect motor ground terminal to electrical service ground.
Bond motor to pool structure. Use a solid copper conductor, size No. 8 AWG
(8.4 sq.mm) or larger. Run wire from external bonding lug (see Fig. 2) to rein-
forcing rod or mesh.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding wire to the pressure
wire connector provided on the motor housing and to all metal parts of the
swimming pool, spa, or hot tub and to all electrical equipment, metal piping
or conduit within 5 feet (1.5 m) of the inside walls of swimming pool, spa, or
hot tub.

Wiring

Pump must be permanently connected to circuit; be sure no other lights or ap-
pliances are on the same circuit. Match wire sizes to Table I (Pg. 5).
NOTICE: To prevent dirt, rain, bugs, etc., from entering motor when not
wiring with conduit, be sure to seal wire opening on end of motor.
Use Ground Fault Circuit Interrupter (GFCI) as master on-off switch; it will
sense a short circuit to ground and disconnect power before it becomes dan-
gerous to pool users. Test according to maker’s instructions.
In case of power outage, check GFCI for tripping (which will prevent normal
water circulation). Reset if necessary.

BONDING

LUG

GREEN 

GROUND 

SCREW

510 0993

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

Figure 2 – Typical ground screw and
bonding lug locations.

Figure 3 – Wiring hook-up diagram

Summary of Contents for PE5YD-133L

Page 1: ...ta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Union City TN Delavan WI M...

Page 2: ...ULLY The Sta Rite PE and PEA Series Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety I...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Page 4: ...to pump with union half use Teflon tape or Plasto Joint Stik between pipe and union adapter Union collar to pump should be assembled dry and hand tight NOTICE Pump suction and discharge connections h...

Page 5: ...conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to...

Page 6: ...e required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG 8 4 sq mm or larger Run wire from external bonding...

Page 7: ...er fill trap and pump with water Lubricate trap cover O Ring with petroleum jelly each time it is removed Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to...

Page 8: ...d by hand 3 Cap inlet piping after draining to keep water out of the pipes 4 To prevent pump from freezing remove the trap cover and drain the tank body through the two drain plugs provided Clean pump...

Page 9: ...ure in trap body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulle...

Page 10: ...l in seal plate NOTICE On 2 HP models install impeller screw left hand thread turn counterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble mo...

Page 11: ...er is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8 Impeller and diffuser...

Page 12: ...12 1 2 3 4 19 20 8 5 6 9 10 11 14 15 16 12 13 17 18 7 21 2243 0196 PE and PEA Series MAX E GLAS 2 Speed Pool Pump 3 4 1 and 2 HP Models...

Page 13: ...s U27 67 Tag CAUTION This pump equipped C63 13 with mech shaft seal Tag CAUTION Securely tighten and C63 10 center trap cover prior to pressure testing Nameplate U33 121 Not illustrated Models PEAXYG...

Page 14: ...haul Kits HP Parts Pak Number 3 4 PP1014 1 PP1016 Kit includes Impeller Diffuser Shaft Seal Gaskets O Rings Hardware Shims Wear Rings and Inserts Seal Gasket Kit Kit includes Shaft Seal Gaskets and O...

Page 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Page 16: ...16...

Reviews: