Bond motor to pool structure. Use a solid copper con-
ductor, size No. 8 AWG (8.4 sq.mm) or larger. Run wire
from external bonding lug (see Figure 3) to
reinforcing rod or mesh.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding
wire to the pressure wire connector provided on the
motor housing and to all metal parts of the swimming
pool, spa, or hot tub and to all electrical equipment,
metal piping or conduit within 5 feet (1.5 m) of the inside
walls of swimming pool, spa, or hot tub.
Wiring
Pump must be permanently connected to circuit. See
Figures 4A and 4B for wiring connection diagrams. Match
wire and circuit breaker sizes to correct Fusing and
Wiring Data Chart (Page 7). If other lights or appliances
are also on the same circuit, be sure to add their amp
loads to pump amp load. (If unsure how to do this or if
this is confusing, consult a licensed electrician.) Use the
load circuit breaker as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit;
it will sense a short-circuit to ground and disconnect
power before it becomes dangerous to pool users. For
size of GFCI required and test procedures for GFCI, see
manufacturer’s instructions.
In case of power outage, check GFCI for tripping (which
will prevent normal water circulation). Reset if necessary.
NOTICE:
If you do not use conduit when wiring motor,
be sure
to seal wire opening on end of motor to prevent
dirt, bugs, etc., from entering motor.
Risk of dangerous or fatal electrical shock.
Be sure that power to the motor circuit is off before
working on wiring, wiring connections, or motor. Re-in-
stall the motor end cover and all other wiring covers be-
fore turning on the power.
1. Turn off power.
2. Remove the motor end cover.
To Wire a Single Speed, Single Voltage Motor
There are two terminals labeled L1 and L2. Attach the
power leads to these terminals. Either wire may attach to
either terminal.
To Wire a Dual-Voltage Motor
Dual voltage motors have a plug to change from 230 volts
(factory setting) to 115 volts.
1. If you have 230 volts motor supply voltage, confirm
that the plug is set for 230 volts. The arrow on the plug
will point to the 230 volt position. Note that plug only
connects with one prong in this position.
2. If you have 115 volt supply, pull the plug straight up
and place it on the
two
brass prongs as shown.
NOTE:
Arrow is highlighted for clarity.
To Wire a Two-Speed Motor
Wire the pump as shown in the diagram.
Figure 4B Voltage Change
Plug Set for 115 Volts
Figure 4A -Voltage Change
Plug Set for 230 Volts
Figure 4C - 2-Speed Motor Wiring Diagram
L
2
=
C
O
M
L
1
=
H
I
A
=
L
O
W
A
L2
L1
Power Supply for
Optional Timer.
Low Speed
High Speed
Circuit
Protector
Remote
SPDT
Switch
Ground (Green)
Common
If using timer, Connect
Timer Motor to Low Speed Only
Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.