background image

6

Bond motor to pool structure. Use a solid copper con-
ductor, size No. 8 AWG (8.4 sq.mm) or larger. Run wire
from external bonding lug (see Figure 3) to 
reinforcing rod or mesh.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding
wire to the pressure wire connector provided on the
motor housing and to all metal parts of the swimming
pool, spa, or hot tub and to all electrical equipment,
metal piping or conduit within 5 feet (1.5 m) of the inside
walls of swimming pool, spa, or hot tub.

Wiring

Pump must be permanently connected to circuit. See
Figures 4A and 4B for wiring connection diagrams. Match
wire and circuit breaker sizes to correct Fusing and
Wiring Data Chart (Page 7). If other lights or appliances
are also on the same circuit, be sure to add their amp
loads to pump amp load. (If unsure how to do this or if
this is confusing, consult a licensed electrician.) Use the
load circuit breaker as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit;
it will sense a short-circuit to ground and disconnect
power before it becomes dangerous to pool users. For
size of GFCI required and test procedures for GFCI,  see
manufacturer’s instructions.
In case of power outage, check GFCI for tripping (which
will prevent normal water circulation). Reset if necessary.

NOTICE:

If you do not use conduit when wiring motor,

be sure

to seal wire opening on end of motor to prevent

dirt, bugs, etc., from entering motor.

Risk of dangerous or fatal electrical shock.

Be sure that power to the motor circuit is off before
working on wiring, wiring connections, or motor. Re-in-
stall the motor end cover and all other wiring covers be-
fore turning on the power. 

1. Turn off power.
2. Remove the motor end cover.

To Wire a Single Speed, Single Voltage Motor

There are two terminals labeled L1 and L2. Attach the
power leads to these terminals. Either wire may attach to
either terminal.

To Wire a Dual-Voltage Motor

Dual voltage motors have a plug to change from 230 volts
(factory setting) to 115 volts.
1. If you have 230 volts motor supply voltage, confirm

that the plug is set for 230 volts. The arrow on the plug
will point to the 230 volt position. Note that plug only
connects with one prong in this position.

2. If you have 115 volt supply, pull the plug straight up

and place it on the 

two

brass prongs as shown.

NOTE:

Arrow is highlighted for clarity.

To Wire a Two-Speed Motor

Wire the pump as shown in the diagram. 

Figure 4B Voltage Change
Plug Set for 115 Volts

Figure 4A -Voltage Change
Plug Set for 230 Volts

Figure 4C - 2-Speed Motor Wiring Diagram

L

2

=

C

O

M

 

 

L

1

=

H

I

 

A

=

L

O

W

A

L2

L1

Power Supply for

Optional Timer. 

Low Speed

High Speed

Circuit

Protector

Remote

SPDT

Switch

Ground (Green)

Common

If using timer, Connect 
Timer Motor  to Low Speed Only

Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.

230
Volt

Lines

Back of
motor
with 
Terminal
Board

4558 0304

Summary of Contents for MAX-E-PRO P6E

Page 1: ...mbers Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S691 Rev 11 18 05 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life ...

Page 2: ...d warns about hazards that can cause death serious personal injury or major property damage if ignored warns about hazards that will or can cause minor personal injury or property damage if ignored NOTICE indicates special instructions not related to hazards Carefully read and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or ...

Page 3: ...bient temperature whenever the pump is running Be solid Level Rigid Vibration free Non com bustible To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be ...

Page 4: ...slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pipes Fittings Fittings restrict flow for best efficiency use fewest possi ble fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical ...

Page 5: ...one main drain suction fitting is completely blocked The flow through the remaining main drain s must com ply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause se vere or fatal electrical shock hazard Do not gro...

Page 6: ...pening on end of motor to prevent dirt bugs etc from entering motor Risk of dangerous or fatal electrical shock Be sure that power to the motor circuit is off before working on wiring wiring connections or motor Re in stall the motor end cover and all other wiring covers be fore turning on the power 1 Turn off power 2 Remove the motor end cover To Wire a Single Speed Single Voltage Motor There are...

Page 7: ...30 60 M 60 90 M 1 20 13 8 115 60 1 12 3 10 5 5 8 8 4 1 1 2 25 16 0 115 60 1 12 3 8 8 4 6 14 1 15 6 9 230 60 1 14 2 14 2 14 2 1 1 2 15 8 0 230 60 1 14 2 14 2 12 3 1 3 4 15 10 4 230 60 1 14 2 12 3 12 3 2 15 10 4 230 60 1 14 2 12 3 12 3 2 1 2 15 11 2 230 60 1 14 2 12 3 12 3 Time delay fuses are recommended instead of standard fuses in any motor circuit Wire Size AWG mm2 Wire Size AWG mm2 TABLE I RECO...

Page 8: ... original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silicone based lubricant Clean and inspect O Ring reinstall on trap Replace trap cover and handle ring on trap turn handle ring clockwise to tighten cover NOTICE Tighten trap cover handle ring by hand only no wrenches Pump should prime ...

Page 9: ...astic For outdoor unprotected installations 1 Gravity drain system as far as possible 2 Protect areas which retain water with non toxic propy lene glycol antifreeze RV antifreeze 3 Enclose entire system in a weatherproof enclosure 4 To avoid condensation corrosion damage allow venti lation do not wrap system in plastic 5 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C Star...

Page 10: ...nt press ce ramic seat into seal plate firmly and squarely with finger pressure Figure 5 2 If ceramic seat will not locate properly remove it place face up on bench and reclean cavity Ceramic seat should now locate 3 If seat still will not locate properly place a cardboard washer over the polished face and use a piece of 3 4 19mm standard pipe for pressing purposes NOTICE Be sure not to scratch or...

Page 11: ...logged follow steps 1 through 7 under Removing Old Seal Page 10 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 10 for re assembly 7 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Page 12 8 Pump may be trying to push too high a column of water If so a higher head pump is needed Electrical 9 Pump may be running too slowly...

Page 12: ... Shaft Seal 1 37400 0028S 8 Clamp Knob 1 C19 37A 9 Clamp 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller Screw O Ring 1 35505 1426 10B Impeller Screw 1 Chart at Right 11 Diffuser 1 Chart at Right 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 Screw w C1 271P Diffuser 5 U30 922SS 14 Screw w C1 271P1 Diffuser 5 U30 542SS 15 Tank Body Assembly 1 17307 0110S 16 Trap Cover Assembly 1 17...

Page 13: ...13 1 5 6 11 12 13 See Box A See Box A 16 18 17 19 15 14 10 10A 7 8 9 3 4 2 2A 21 22 23 24 20 10B 4285 1102 P6E P6EA P6RA MAX E PRO TM POOL PUMP 1 2 through 3 HP Models ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...ulbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties relate to the original consumer purchaser Purchaser only Sta Rite Industries shall have the option to re pair or replace the defective product at its sole discretion Purchasers must pay all labor an...

Reviews: