background image

2. Use equipment only in a pool or spa installation.
3. Install pump with at least 2 hydraulically balanced

main drains equipped with correctly installed, screw-
fastened, anti-entrapment certified covers. See Page 4.

4. Trapped air in system can cause explosion. BE SURE 

all air is out of system before operating or testing 
equipment.

Before pressure testing, make the following safety

checks:

• Check all clamps, bolts, lids, and system accessories

before testing.

• Release all air in system before testing.

Water pressure for test must be less than 25 PSI
(7.5 kg/cm

2

).

• Water Temperature for test must be less than 100

o

F

(38

o

C).

• Limit test to 24 hours. After test, visually check system

to be sure it is ready for operation. Remove trap lid and
retighten hand tight only.

NOTICE:

These parameters apply to Sta-Rite equipment

only. For non-Sta-Rite equipment, consult manufacturer.

INSTALLATION

Only qualified, licensed personnel should install pump
and wiring.

Pump mount must:

Be located away from corrosive or flammable chemicals.
Have enough ventilation to maintain air temperature at less
than the maximum ambient temperature rating (Max. Amb.)
listed on the motor model plate. If this pump is installed in
an enclosure/pump house, the enclosure must have ade-
quate ventilation and air circulation to keep the tempera-
ture in the enclosure at or below the motor’s rated ambient
temperature whenever the pump is running.
Be solid - Level - Rigid - Vibration free - Non-com-
bustible. (To reduce vibration and pipe stress, bolt pump
to mount.)
Allow pump suction inlet height to be as close to water
level as possible.
Allow use of short, direct suction pipe (To reduce friction
losses).
Allow for gate valves in suction and discharge piping.
Have adequate floor drainage to prevent flooding.
Be protected from excess moisture.
Allow adequate access for servicing pump and piping.

3

IMPORTANT SAFETY 
INSTRUCTIONS

Always follow basic safety precautions with this
equipment, including the following.

To reduce the risk of injury, do not per-

mit children to use this product unless they are closely
supervised at all times.

This pump is for use with permanently

installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is con-
structed so that it may be readily disassembled for stor-
age and reassembled to its original integrity.

SAVE THESE 
INSTRUCTIONS

Suction

Port 

from

pool or

vacuum

filters

Strainer Basket

cover

Discharge Port

to filter

or pool

Clamp

Knob

Bonding Lug

Pump may be bolted to level 

foundation or mounting bracket

4284 1102

Figure 1

NOTICE: 

Port threads are: Internal - 2" NPT for direct connection

to pipe. External - 3-1/4" Buttress. Fits Sta-Rite U11-200P Union
Collar for quick disconnect pipe connection.

See Page 12 for Union Kits.

Summary of Contents for MAX-E-PRO P6E

Page 1: ...mbers Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S691 Rev 11 18 05 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life ...

Page 2: ...d warns about hazards that can cause death serious personal injury or major property damage if ignored warns about hazards that will or can cause minor personal injury or property damage if ignored NOTICE indicates special instructions not related to hazards Carefully read and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or ...

Page 3: ...bient temperature whenever the pump is running Be solid Level Rigid Vibration free Non com bustible To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be ...

Page 4: ...slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pipes Fittings Fittings restrict flow for best efficiency use fewest possi ble fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical ...

Page 5: ...one main drain suction fitting is completely blocked The flow through the remaining main drain s must com ply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause se vere or fatal electrical shock hazard Do not gro...

Page 6: ...pening on end of motor to prevent dirt bugs etc from entering motor Risk of dangerous or fatal electrical shock Be sure that power to the motor circuit is off before working on wiring wiring connections or motor Re in stall the motor end cover and all other wiring covers be fore turning on the power 1 Turn off power 2 Remove the motor end cover To Wire a Single Speed Single Voltage Motor There are...

Page 7: ...30 60 M 60 90 M 1 20 13 8 115 60 1 12 3 10 5 5 8 8 4 1 1 2 25 16 0 115 60 1 12 3 8 8 4 6 14 1 15 6 9 230 60 1 14 2 14 2 14 2 1 1 2 15 8 0 230 60 1 14 2 14 2 12 3 1 3 4 15 10 4 230 60 1 14 2 12 3 12 3 2 15 10 4 230 60 1 14 2 12 3 12 3 2 1 2 15 11 2 230 60 1 14 2 12 3 12 3 Time delay fuses are recommended instead of standard fuses in any motor circuit Wire Size AWG mm2 Wire Size AWG mm2 TABLE I RECO...

Page 8: ... original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silicone based lubricant Clean and inspect O Ring reinstall on trap Replace trap cover and handle ring on trap turn handle ring clockwise to tighten cover NOTICE Tighten trap cover handle ring by hand only no wrenches Pump should prime ...

Page 9: ...astic For outdoor unprotected installations 1 Gravity drain system as far as possible 2 Protect areas which retain water with non toxic propy lene glycol antifreeze RV antifreeze 3 Enclose entire system in a weatherproof enclosure 4 To avoid condensation corrosion damage allow venti lation do not wrap system in plastic 5 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C Star...

Page 10: ...nt press ce ramic seat into seal plate firmly and squarely with finger pressure Figure 5 2 If ceramic seat will not locate properly remove it place face up on bench and reclean cavity Ceramic seat should now locate 3 If seat still will not locate properly place a cardboard washer over the polished face and use a piece of 3 4 19mm standard pipe for pressing purposes NOTICE Be sure not to scratch or...

Page 11: ...logged follow steps 1 through 7 under Removing Old Seal Page 10 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 10 for re assembly 7 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Page 12 8 Pump may be trying to push too high a column of water If so a higher head pump is needed Electrical 9 Pump may be running too slowly...

Page 12: ... Shaft Seal 1 37400 0028S 8 Clamp Knob 1 C19 37A 9 Clamp 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller Screw O Ring 1 35505 1426 10B Impeller Screw 1 Chart at Right 11 Diffuser 1 Chart at Right 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 Screw w C1 271P Diffuser 5 U30 922SS 14 Screw w C1 271P1 Diffuser 5 U30 542SS 15 Tank Body Assembly 1 17307 0110S 16 Trap Cover Assembly 1 17...

Page 13: ...13 1 5 6 11 12 13 See Box A See Box A 16 18 17 19 15 14 10 10A 7 8 9 3 4 2 2A 21 22 23 24 20 10B 4285 1102 P6E P6EA P6RA MAX E PRO TM POOL PUMP 1 2 through 3 HP Models ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...ulbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties relate to the original consumer purchaser Purchaser only Sta Rite Industries shall have the option to re pair or replace the defective product at its sole discretion Purchasers must pay all labor an...