Technical Information

Maximum Ratings:

                                               3450RPM, P1 1375W, P2 1100W, 10.0A

IP Rating:

IP25

Inlet (Suction):

ABS Barrel Union to suit 50mm PVC pressure pipe

to AS/NZS 1477

Outlet (Discharge):

ABS Barrel Union to suit 50mm PVC pressure  pipe

to AS/NZS 1477

Max Working Pressure:

260 kPa

Water Temperature Range:

5°C – 40°C

Maximum Ambient temperature:  

5 5°C

Recommended pH Range:

7.2 - 7.8 (Guide Only)

Sound Power Level (Lwa):

Motor:

            

Radial flux, permanent magnet, DC

Protection: 

Mains over voltage, mains under voltage, over temperature,

                     under temperature, locked rotor, over current, phase disconnect.

Supply cord: 

10A, H07RNF, 2m.

Low:         69dB

                                                Med:         63dB
                                                High:        57dB

Override:  73dB

?

4

RPM:

Step1

2600RPM (4 hours) default factory setting

Step2

2100RPM (4 hours) default factory setting

Step3

1600RPM (4 hours) default factory setting

Override / Adjustable Range:

600-3450RPM (2 hours)

Rated Current:

Step1 

5.4A (max)

                

Step2 

3.2A (max)

               

Step3 

1.7A (max)

Override:

10.0A

Input Power (P1):

Step1

690W (max)

                                                                Step2

375W (max)

                                                                Step3

180W (max)

Override:

1375W (max)

Pump Power (P2):

Step1

550W (max)

                                                                Step2

300W (max)

                                                                Step3

145W (max)

Override:

1100W (max)

Model:

  

enviroFLO 1100

Electrical Rating:

230-240V 50Hz single phase

1

1

0

0

enviro

MAX

L300241_EnviroMAX_OM

Monday, 11 August 2014 10:18:34 AM

Summary of Contents for enviroMAX

Page 1: ... of equipment you should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product The pump operator or owner must be provided with this owner s manual For the Installation Operation and Service of the Variable Speed Pool Pump 1 1 0 0 enviroMAX ...

Page 2: ...perating the pump Variable speed adjustment Operating the pump Control panel operation Operating the pump Override Operating the pump Schedule advance Operating the pump Key lockout Operating the pump Time out Operating the pump Factory defaults External control Service Maintenance Troubleshooting Troubleshooting Guide Spare Parts Pump parts exploded view Spare parts table Page 3 4 5 5 6 6 7 7 7 8...

Page 3: ... energy savings and extended pump life A specially designed sound dampening pump casing and base make pump operation incredibly quiet Constructed of our durable thermoplastic composite resin so you can be sure it will stand up to the harshest conditions A heavy duty construction and a motor rated for continuous operation make the enviroMAX a tough long lasting performer The high capacity trap hold...

Page 4: ...ains under voltage over temperature under temperature locked rotor over current phase disconnect Supply cord 10A H07RNF 2m Low 69dB Med 63dB High 57dB Override 73dB 4 RPM Step1 2600RPM 4 hours default factory setting Step2 2100RPM 4 hours default factory setting Step3 1600RPM 4 hours default factory setting Override Adjustable Range 600 3450RPM 2 hours Rated Current Step1 5 4A max Step2 3 2A max S...

Page 5: ...e Dimensions Sta rite enviroMAX Performance Chart 5 1 1 0 0 enviroMAX 0 0 5 0 10 0 15 0 20 0 25 0 0 0 100 0 200 0 300 0 400 0 500 0 Head m Flow L min 3450RPM 3100RPM 2850RPM 2600RPM 2350RPM 2100RPM 1850RPM 1600RPM 1350RPM 1100RPM 850RPM 600RPM ...

Page 6: ...osure pump house the enclosure must have adequate ventilation 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level rigid and vibration free d To reduce vibration and pipe stress bolt pump to mount Fixing holes accept 12mm fasteners e Be within 2m of a power out...

Page 7: ... If RCD trips and will not reset have a qualified electrician inspect and repair electrical system c Incorrect voltage can cause fire or seriously damage pump and voids warranty d Voltage at pump must not be more than 6 above or 10 below motor nameplate rated voltage or pump may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 106 of rated volta...

Page 8: ... original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes if present c Remove the trap lid turn anti clockwise d Fill trap tank with water e Check the lid o ring and sealing surface ensure there is no dust or debris on either and replace the lid turn clockwise to tighten by ha...

Page 9: ...nviroMAX 2 Control panel overview CAUTION If power is connected to the enviroMAX motor pressing any of the following buttons referred to in this section could result in the motor starting Failure to recognize this could result in personal injury or damage to equipment Note The START button must be pressed for the pump to operate The START LED will illuminate after the button has been pressed indic...

Page 10: ...speed by one level with 600rpm as the minimum limit Press to increase speed by one level with 3450rpm as the maximum limit The speed setting will be automatically saved or or Note If power is cycled to the pump and the user does not press the STOP key the pump will automatically start and run the programmed default schedule shown in the chart above This feature ensures that the pump will re start ...

Page 11: ...e user will need to press START to begin the 24 hour schedule operation However if START was already pressed prior to receiving a digital input then the pump will resume running the 24 hour schedule once the digital input is removed Note Pressing STOP at any time turns the pump OFF and clears the start time for the 24 hour schedule Operation 3c Operating the pump Operating the enviroMAX from the c...

Page 12: ... and the Schedule Advance mode will be canceled Note While the pump is in the Schedule Advance mode if a user presses the STOP key then the Schedule Advance mode is canceled Note If power is lost while the pump is in the Schedule Advance mode then the 24 hour schedule will automatically start when power is restored 3e Operating the pump Schedule advance Operation 1 1 0 0 enviroMAX 3f Operating the...

Page 13: ... will return to normal operation and accept an input from an automation input source Note If the pump is operating from automation input the 0 RPM LED of the bar graph will blink once every second indicating the temporary stop feature has been activated After the specified time period the pump will return to normal operation and accept an input from any automation input source Refer to page 14 for...

Page 14: ...VDC GND EXTERNAL SUPPLY Automation System or Solar System Controller Figure 6 Wiring Diagram for Automation Control System Inputs Figure 7 Automation Control System Input Connector CAUTION Access to these terminals is in close proximity to the mains connectors which carry line voltage capable of causing personal injury or damaging the equipment if contact is made Power should be turned off when ac...

Page 15: ...perating If leaks are noticed clean and grease the o rings or replace if necessary Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal Call a Pentair Service Agent immediately to prevent damage to the motor Check pump and motor for insects and pest infestations and ensure that motor fins are clean of dust and dirt Clean if necessary Foll...

Page 16: ...sing and strainer are full of water Refer priming instructions Make sure there are no leaks in suction piping and ensure all o rings are present and clean Make sure suctions pipe inlet is well below the water level to prevent pump from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either ins...

Page 17: ...ges Ensure adequate ventilation and reduce ambient temperature Switch off the power to the pump Tighten the casing bolts or replace the mechanical seal as required No water coming from pump pump is working Pump does not work Pump running too slow Water leaking from between the casing and motor Motor fault No power at outlet Blown fuse Circuit breaker Low speed setting Motor high temperature limit ...

Page 18: ...Spare Parts 1 1 0 0 enviroMAX 19 ...

Page 19: ...L UNION KIT INCLUDES 19a 19b 19c x2 19a COLLAR UNION 2 SLIP 19b COLLAR UNION 2 19c ORING Collar Union 20 BASE 21 SCREW 5 16 14 x 1 22 MOTOR PAD BASE KIT INCLUDES 19 20 21 1 MOTOR 1 4 1 1 1 1 1 1 1 1 7 1 1 1 1 2 6 6 10 1 1 1 2 2 2 1 2 1 1 801927 405697 See Motor See Motor Fasteners Kit 801279 C3 184P 801428 800900 1660500 801426 801280 See Pump Casing Assembly C176 71P 801245 801281 See Barrel Unio...

Page 20: ...r service Phone 0800 654 112 Fax 0800 806 642 National dealer locator Phone 0800 664 269 Email nz sales pentair com Web www pentair co nz International Australia New Zealand Phone 61 3 9709 5800 Fax 61 3 9709 5888 Information contained here in remains the property of Pentair Australia Pty Ltd Any reproduction display publication modification or distribution is strictly prohibited without the prior...

Reviews: