background image

Owner’s Manual

PRINTED IN CANADA

CHAuFFE-PIsCINE

COMMERCIAL

 POOl HEAT PumP

Summary of Contents for TH-150

Page 1: ...Owner s Manual PRINTED IN CANADA CHAuFFE PIsCINE COMMERCIAL POOl HEAT PumP ...

Page 2: ...8 Water piping 9 Electrical 10 Bonding 11 Bonding and plumbing step by step instructions 11 Electrical Connections 12 Electrical Diagrams 13 Service Analyzer Control 14 Electronic Temp Controls 14 Initial Startup 17 Meaning of Display Codes 18 Troubleshooting 19 Requesting Assistance or Service 21 Maintenance 22 Winterizing 22 Pool Heat Pump Warranty 23 Table of contents ...

Page 3: ... against corrosion All components are of superior quality which presents you with an effective state of the art technology heat pump In general compared to other types of pool heaters such as gas or oil fired the THERMEAU pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally it may be necessary t...

Page 4: ...o record the purchase date of your device and your dealer s name address and telephone number Model Number_____________________________________________________ Serial Number______________________________________________________ Purchase Date_____________________________________________________ Dealer Name_______________________________________________________ Dealer Address________________________...

Page 5: ... to the completion of a task CAUTION The CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particularly to the product up to the destruction of part or all of the product WARNING The WARNING sign denotes a hazard It calls attention to a procedure practice or the like which i...

Page 6: ...tion and heating CAUTION Proper pool chemistry is vital to the life of your heater Pay particular attention to the total alkalinity and TDS It is highly recommended that you have your pool chemistry checked often by an independent pool store Water quality standards that must be strictly observed Description Normal Range Verification pH level 7 2 to 7 8 Once week Chlorine concentration 1 0 to 3 0 p...

Page 7: ...28 000 4 3 128 000 4 3 Compressor HP 7 7 5 2x5 10 10 Compressor type Scroll Scroll Scroll Scroll Scroll Heat exchanger Titanium PVC Titanium PVC Titanium PVC Titanium PVC Titanium PVC Heating range F C Up to 104 F 40 C Up to 104 F 40 C Up to 104 F 40 C Up to 104 F 40 C Up to 104 F 40 C Voltage Hz Ph 208 240 60 1 208 240 60 3 208 240 60 1 208 240 60 3 575 600 60 3 Required breaker 60 40 60 60 30 Mi...

Page 8: ...ting capacity and efficiency The unit should be located as close as practical to the existing pool pump and filter to minimize water piping However do not forget to provide a 18 clear ance at the very least all around your heat pump Mount the unit on a sturdy base preferably a concrete slab or a set of blocks The size of the base should not be less than 40 x 40 100 cm x 100 cm All THERMEAU pool he...

Page 9: ...nts should be glued with PVC glue If rigid PVC is not available you can use soft or flexible piping with stainless steel clamps When the piping installation is complete operate the pool pump and check the system for leaks Then check the filter pressure gauge to verify that there isn t any indication of excessive pump head pressure You can also make the connections using high pressure flexible hose...

Page 10: ...eat pump installations must be done in parallel An equal flow of water to each heat pump is important for optimum operation NOTE It may be necessary to adjust water pressure switch if a unit is installed below the water level Each heat pump allows a maximum flow rate of 125 gpm 473 L min and requires a minimum of 60 gpm 227 L min ...

Page 11: ...tal the heater any automatic chlorine generator and any other metal or electrical equipment On some older pools this substructure bond wire may not exist In these cases a 6 to 8 foot solid copper rod must be driven into the ground near the equipment All electric and metal components must then be bonded to each other and then to the copper rod WARNING 1 A 1 3 lb check valve must be installed betwee...

Page 12: ... the phase are in wrong sequence that ll be the FAULT red light that come ON and the compressor won t start If this occurred you have to switch the L1 wire with L2 wire WARNING L3 L2 L2 L1 L1 Ground Ground ON FAULT Electrical Connections The installation of the THERMEAU pool heater should be performed by a cer tified electrician To connect the electricity you must unscrew the four screws of the fr...

Page 13: ...13 Owner s manual CHAuFFE PIsCINE COMMERCIAL POOl HEAT PumP ...

Page 14: ... units Description The control located on the front of your heat pump has a large three character display for the water temperature set points and diagnostics see figure 5 for front panel appearance The three button keypad includes SET DOWN arrow and UP arrow buttons LED indicators next to the display show if the heat pump is in the pool mode or in the spa mode and if the unit is running Service A...

Page 15: ...t range is OFF and 61 F to 104 F Pushing the UP arrow or DOWN arrow buttons will prompt the control to display the current set point Continuing to press the UP or DOWN buttons will allow the set point values to scroll until the desired set point is reached Once the new set point has been reached stop pressing the UP or DOWN buttons Once the unit toggles back to the current water temperature displa...

Page 16: ...th 2 wires to the P S terminal on control board Figure 6 shows you where to connect the 2 wire remote systems to the temperature controller For 3 wire remotes 1 Bring up POL setting and use arrows to select desired pool temperature 2 Bring up SPA setting and use the arrows to select the desired spa tem perature 3 Set unit to POL mode 4 Connect the commun and high or spa wires to the P S terminals ...

Page 17: ...ter dripping from the holes at the base of the unit This is simple condensation Connection to AquaLink Compool Hayward AquaLogic or any other 2 wire remote system with their own thermostat Remove gray jumper from terminals 1 and 2 on TB1 Bring the two wires from the remote system to terminals 1 2 on Terminal Block 1 TB1 The Temperature Control knob must be turned clockwise highest temp setting for...

Page 18: ...r 3 HP faults This will stop your heater for protection Po Water temperature probe connected to 1 and 2 on electronic board may be disconnected If it is not the probe may be open or defective Pc Water temperature probe is short circuited or may be defective FLo FL3 Possible causes The FIL parameter must always be set to OFF The filter is in backwash position The filter pump is stopped The filter i...

Page 19: ...r the display stops indicating FS The fan is running but the compressor is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying flo and it will not start Heat pump control set to OFF Desired water temperature is reached Main breaker is tripped Raise temperature set point above 60 F 15 C Unit will automatica...

Page 20: ...ater is in the heating mode a large quantity of warm and humid air passes over the evaporator and causes con densation It is normal to see condensation dripping under the heater To check if the water really is a leak you must stop the heater and leave the pool pump running for over 5 hours If water is still coming out of your heater after this period then call your dealer for service There is wate...

Page 21: ...ubleshooting p 19 20 and Warranty p 23 sections or call your dealer It may save you the cost of a service call If you still need help follow the instructions below Service can be obtained by calling one of these phone numbers CANADA and USA 1 418 661 2222 When asking for help please provide a detailed description of the problem your heater s complete model and serial number and the purchase date s...

Page 22: ... with the help of a brush and soap Winterizing First you must turn the breaker off The unit must be drained of all its water You will need to disconnect the IN and OUT water connections Then the unit must be tilted or blown out with air until all water is out The next step is to reconnect your IN and OUT water connections that will have previously been drained It is recommended to cover the heat p...

Page 23: ...rt is warranted All Thermeau Industries inc pool heat pump must be installed according to manufacturer s specifications or the warranty will be null and void All warranty work must be performed by a Thermeau Industries inc authorized service center All warranty work must be approved prior to service center performing the work Any alteration or repair by any person agency or company not authorized ...

Page 24: ...CHAuFFE PIsCINE COMMERCIAL POOl HEAT PumP ...