background image

3

READ AND FOLLOW SAFETY
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system

or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that 

will

cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that 

can

cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that 

will

or 

can

cause minor personal injury

or property damage if ignored.

NOTICE 

indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip-
ment. 

Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 

Read and follow instructions in owner's manual when installing
and operating equipment. Have a trained pool professional per-

form all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.

Water pressure for test must be less than 25 PSI (7.5 kg/cm

2

).

• Water Temperature for test must be less than 100

o

F. (38

o

C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready

for operation. Remove trap lid and retighten hand tight only.

NOTICE:

These parameters apply to Sta-Rite equipment only. For 

non-Sta-Rite equipment, consult manufacturer.

IMPORTANT

SAFETY 

INSTRUCTIONS

Always follow basic safety pre-
cautions with this equipment, in-
cluding the following.

To reduce the risk of

injury, do not permit children to
use this product unless they are
closely supervised at all times.

This pump is for use

with permanently installed pools
and may also be used with hot
tubs and spas if so marked. Do
not use with storable pools. A
permanently installed pool is con-
structed in or on the ground or in
a building such that it cannot be
readily disassembled for storage.
A storable pool is constructed so
that it may be readily disassem-
bled for storage and reassembled
to its original integrity.

SAVE THESE 

INSTRUCTIONS

Summary of Contents for DYNA-GLAS

Page 1: ...3115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga Ont Murrieta CA Printed in U S...

Page 2: ...3 Installation 4 5 Pool Pump Suction Requirements 5 6 Electrical 7 8 Operation 9 Storage Winterizing 9 10 Pump Service 11 12 Troubleshooting Guide 12 13 Repair Parts List 14 15 Warranty 16 Single Spee...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Page 4: ...piping Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign matter to col lect around the pump motor To avoid burns when handli...

Page 5: ...low for a pump installation which minimizes risk to users of pools spas and hot tubs Entrapment Protection The pump suction system must provide protection against the hazard of suction entrapment or h...

Page 6: ...tions Testing and Certification Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction Fitti...

Page 7: ...g wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 feet 1 5...

Page 8: ...2 1 2 15 11 9 3 5 230 60 1 14 2 14 2 12 3 2 15 10 4 230 60 1 14 2 14 2 12 3 2 1 2 15 11 2 230 60 1 14 2 14 2 12 3 MPFA SERIES SINGLE SPEED 3 4 15 15 9 9 5 0 115 230 60 1 14 14 2 2 10 14 5 5 2 10 14 5...

Page 9: ...ate the trap cover O Ring The original equipment O Ring con tains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silico...

Page 10: ...ezing remove trap cover and drain the tank body through the two drain plugs provided A Gravity drain system as far as possible B Protect areas which retain water with non toxic propylene glycol antifr...

Page 11: ...e in trap body remove cover unscrew by turn ing counterclockwise 3 Remove 6 nuts lockwashers and flat washers holding seal plate to pump body Pull seal plate and motor away from pump body You may have...

Page 12: ...impeller onto shaft clockwise this will automatically locate seal in seal plate NOTICE On 2 and 2 1 2 HP models install impeller gasket and lock screw left hand thread turn counterclockwise Torque lo...

Page 13: ...ay be running too slowly check voltage at motor terminals and at meter while pump is running If low see wiring instructions or consult power company Check for loose connections 11 Pump may be too hot...

Page 14: ...148L 1 1 2 AE100FLL MPFA6D 176L 3 4 A100DLL MPFA6E 146L 1 A100ELL MPFA6F 147L 1 1 2 A100FLL 230 60 1 MPRA6G 155L 2 A100GLL MPEA6G 155L 2 AE100GLL MPEAA6G 168L 2 1 2 AE100G5LL Two Speed 230 60 1 MPRA6Y...

Page 15: ...Ring 1 U9 375 U9 375 U9 375 U9 375 U9 375 14 Trap Basket 1 C8 58P C8 58P C8 58P C8 58P C8 58P 15A Drain Plug 2 U178 920P U178 920P U178 920P U178 920P U178 920P 15B Mounting Screw 5 16 14x5 8 2 U30 9...

Page 16: ...pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace t...

Reviews: