SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t start or run.

Blown fuse.

If blown, replace with fuse of proper size.

Low line voltage.

If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro authority.

Defective motor.

Replace pump.

Defective float switch.

Replace float switch.

Impeller.

If impeller won’t turn, remove lower pump body and locate source of binding.

Float obstructed.

Remove obstruction.

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace float switch.

Pump won’t shut off.

Defective float switch.

Replace float switch.

Restricted discharge 

Remove pump and clean pump and piping.

(obstacle in piping).

Float obstructed.

Remove obstruction.

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring from main

delivers little or no water.

switch on property. If OK, contact power company or hydro authority.

Something caught in impeller.

Clean out impeller.

Worn or defective parts or

Clean impeller if plugged; otherwise replace pump.

plugged impeller.

Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump 

vent hole.

discharge & check valve.

TROUBLESHOOTING CHART

LIMITED WARRANTY

STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be
free from defects in material and workmanship for the Warranty Period shown below.

Product

Warranty Period

Water Systems Products — jet pumps,

whichever occurs first:

small centrifugal pumps, submersible pumps

12 months from date of original installation, or

and related accessories

18 months from date of manufacture

Pro-Source

TM

Composite Tanks

5 years from date of original installation

Pro-Source

TM

Steel Pressure Tanks

5 years from date of original installation

Pro-Source

TM

Epoxy-Lined Tanks

3 years from date of original installation

Sump/Sewage/Effluent Products

12 months from date of original installation, or
18 months from date of manufacture

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication,
improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single
phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by
three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and STA-RITE’s only duty, is that STA-RITE repair or replace defective products (at STA-RITE’s choice).
You must pay all labor and shipping charges associated with this warranty and must request warranty service through the
installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty
Period has expired. This warranty is not transferable.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES 
WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE
DURATION EXPRESSLY PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration
of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal
rights and You may also have other rights which vary from state to state.

This warranty supersedes and replaces all previous warranty publications.

STA-RITE INDUSTRIES

293 Wright St., Delavan, WI  53115

Summary of Contents for D125 Series

Page 1: ...elease all pressure within system before servicing any component 4 Drain all water from system before servicing 5 Secure discharge line before starting pump An unse cured discharge line will whip poss...

Page 2: ...c pipe A For D125 D133 and D150 Series Wrap thread with Teflon tapeTM Screw pipe into pump hand tight 1 1 1 2 turns Thread outlet pipe into pump body carefully to avoid stripping or crossing threads B...

Page 3: ...se shut off unit immediately Water level is probably very low and unit has broken prime NOTICE For continuous operation water depth must be at least 5 127mm to prevent motor overheating AUTOMATIC FLOA...

Page 4: ...1 PS1 21P PS1 21P PS1 21P 8 Impeller 1 See Chart Below See Chart Below See Chart Below 9 Volute Lower 1 FP0005781 FP0005781 FP0005781 10 Screw 8 16x1 2 Lg Pan Head 7 U30 934ZP U30 934ZP U30 934ZP Scr...

Page 5: ...Switch Cord Clamp 1 CC0030 13 CC0030 13 6 Nut Acorn SS 1 U36 203SS U36 203SS 7 Screw Panhead 1 U30 971SS U30 971SS 8 Automatic Float Switch Assembly 1 PS17 109 PS17 111 9 Upper Pump Housing 1 12920 1...

Page 6: ...Pro SourceTM Steel Pressure Tanks 5 years from date of original installation Pro SourceTM Epoxy Lined Tanks 3 years from date of original installation Sump Sewage Effluent Products 12 months from date...

Page 7: ...dentro del sistema antes de realizar tra bajos de reparaci n o mantenimiento en cualquiera de los com ponentes 4 Drene toda el agua del sistema antes de realizar trabajos de reparaci n o mantenimient...

Page 8: ...on cinta de Tefl nTM Atornille el tubo en la bomba a mano dando entre 1 y 1 1 2 vueltas Enrosque el tubo de sali da en el cuerpo de la bomba con cuidado para evitar que las roscas se deformen o se cru...

Page 9: ...undidad del agua debe ser por lo menos de 5 127 mm para evitar que el motor se recaliente CONMUTADOR AUTOM TICO DE FLOTACI N INSTALACI N 1 Instale la bomba siguiendo las instrucciones de instalaci n y...

Page 10: ...illo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS U30 951PS 6 Motor 1 7 Voluta superior 1 PS1 21P PS1 21P PS1 21P 8 Impulsor 1 Ver tabla a continuaci n Ver tabla a continuaci n Ver tabla a continua...

Page 11: ...l conmutador 1 CC0030 13 CC0030 13 6 Tuerca ciega SS 1 U36 203SS U36 203SS 7 Tornillo cabeza de cono achatado 1 U30 971SS U30 971SS 8 Ensamblaje del conmutador autom tico de flotaci n 1 PS17 109 PS17...

Page 12: ...8 meses desde la fecha de fabricaci n Tanques de compuesto Pro SourceMC 5 a os desde la fecha de la instalaci n inicial Tanques a presi n de acero Pro SourceMC 5 a os desde la fecha de la instalaci n...

Reviews: