7.5
Factory data display
Figure 18.
GUI factory data panel
Like faults history, factory data are sent at each
power up.
The table below shows the factory data parameters and lists some fields as examples for a possible user
application.
Table 3.
GUI E²P parameter description
Voltage monitoring
Vout1
Customer factory field, not used by firmware nor GUI
Vout2
Vout3
Vout4
Calibration Data
PFC Voltage
Customer factory field, not used by firmware nor GUI
Wattage
L_Param
PFC inductance, used by the power computation algorithm
Time Record
Running Time
Power supply cumulated active time
On/Off Cycles
Number of power supply restart events
Error Count
Number of errors
Serial Number Data
Serial Number, 20 char
Customer factory field, not used by firmware nor GUI
UM2342
Factory data display
UM2342
-
Rev 1
page 18/57