Ashby-P Insert
31
3. The Heat Level button will advance the setting up and down between level 1 and 5. It
will also be used in the Fine Tuning process of the feed rates if needed.
To adjust the Feed-rates:
Hold the Auger Feed Button down and press the Heat Level High/Low button and this
will change the ON Time up or down .25 seconds from the factory setting. Watch the
LED lights to see the setting is on (it will flash the new setting). This new setting will
stay in memory from this point on. The LED lights indicate the level of adjustment and
the factory setting is the center LED light. This gives two .25 second adjustments up and
two .25 second adjustments down.
4.
The Trim button is used to adjust the Exhaust (Combustion) fan voltages up or down
to provide for
fine-tuning
of the combustion air. The LED lights indicate the level of
adjustment and the factory setting is the center LED light. This gives 2 adjustments up
and 2 adjustments down.
To adjust the Combustion Fan voltages:
Hold the Auger Feed button down and press the Trim High/Low button and this will
change the fan voltage approximately 2.5 volts up or down from the factory setting.
Watch the LED lights to see the setting is on (it will flash the new setting). This new
setting will stay in memory from this point on.
Use these adjustments in conjunction
with the damper.
5. The Thermostat Slide switch allows the Insert to be run in 3 different Modes:
a.
Manual Mode
. The Control Board controls all functions of the Ashby.
b.
T-Stat Mode
.
The Stove is Fully-Automatic in the T-Stat Mode.
(T-Stat requires the
stove be turned on at the control board the first time).
The unit is hooked to a
Thermostat and when calling for heat the unit will advance to the Heat level set at the
Control board. Once the Heat demand has been met, the Stove will immediately shut
down. Use this setting when heating a small area or when Temperatures are
Moderate.
Not recommended for use with a mixture of Pellets and Corn.
c.
SmartStat Mode
. (
Can only be used with Pellets & Cherry Pits in the Ashby –P
model. Not recommended for use with a mixture of Pellets and Corn.
The unit is
hooked to a Thermostat and when calling for heat the Insert will advance to the Heat
level set at the Control board. Once the Heat demand has been met the Insert will
drop to the #1 Heat Level setting
and pilot for one hour
. If the Thermostat does not
call for heat during that hour the unit shuts off and
re-lights itself the next time the
Thermostat calls for heat
. This setting is best used during early Fall or late Spring,
when constant heat is not needed.
6.
Cleaning Cycle.
The Ashby-P only uses Programs 3 & 4. This allows the Ashby-P to
operate in an Automatic mode using the Igniter. These 2 programs have a Cleaning
Cycle built into them that allows
the unit to drop to the #1 level for 5 minutes on
timed intervals. During the cleaning cycle the Combustion Fan will run at line voltage
to blow excess ash from the burn pot. This feature only functions if the unit is
operating on levels 3 through 5.
The ON/OFF light blinks during this cycle
.