5
Application
Access door loudspeaker controller
extension in switch panel housing
with 4 outputs and 2 inputs.
A maximum of 3 ATLCE 670-…
units can be connected in series to
an ATLC 670-… by means of ribbon
cable.
Application
The Access door loudspeaker con
-
troller extension ATLCE 670-… can
be operated in conjunction with the
ATLC 670-… The device is used to
provide 4 additional outputs and
2 additional inputs for the Access
system.
The inputs/outputs at the
ATLCE 670-… are programmed
independently of each other.
In Access systems with several
ATLC 670-… units, if required up
to 3 ATLCE 670-… units can be
installed at each ATLC 670-…
Any other application is deemed not
in accordance with its intended use
and exonerates the manufacturer
from any liability.
Note
•
Mounting, installation and ser
-
vicing work on electrical devices
may only be performed by a suitably
qualified electrician.
•
In order to guarantee the overall
performance scope, the software
must always be updated to the latest
version (from version 1.3.0).
Scope of supply
•
Access door loudspeaker controller
extension for top hat rail mounting
•
2 ribbon cables, one with 115 mm
and one with 350 mm, in order to
connect the ATLCE 670-… to the
ATLC 670-…/the ATLCE 670-…
• this product information
English
Mounting
1
Connect Access door loudspeaker
controller ATLC 670-… and Access
door loudspeaker controller exten
-
sion ATLCE 670-… using the pro
-
vided ribbon cable.
Mount the Access door loudspeaker
controller extension ATLCE 670-…
on the top hat rail on the right next
to the Access door loudspeaker
controller ATLC 670-… or in the
next row.
2
When connecting ATLC 670-…
to ATLCE 670-…/or connecting two
ATLCE 670-… units together, pay
attention to the “OUT“ and “IN“!
3
Wiring diagram
a)
If door releases or gate control
systems are fitted and their con
-
nected values do not correspond to
12 V AC/DC and min. 20 Ohm, then
either switching output 2 (ATLC ter
-
minals 13/14 (output)) or switching
output 3 (ANG terminals 11/12/14
(output)) can be used as a potential-
free door release contact.
To use switching output 2 or 3 as a
potential-free door release contact,
you must configure the corre
-
sponding ATLC switching output in
the Access administration interface.
For more information on the wiring
diagrams, please refer to the Access
System Manual.
Terminal assignment
15
16
Input 1
via potential-free
contact
17
18
Input 1
galvanically isolated
4-30 V DC, 10 mA
25
26
Input 2
via potential-free
contact
27
28
Input 2
galvanically isolated
4-30 V DC, 10 mA
11
12
14
Output 1 changeover contact
30 V AC/DC, 2 A
21
22
24
Output 2 changeover contact
30 V AC/DC, 2 A
31
34
Output 3 working contact
30 V AC/DC, 2 A
41
44
Output 4 working contact
30 V AC/DC, 2 A
Specifications
Protection system: IP 20
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 3
Dimensions (mm) W x H x D:
53.5 x 89 x 60