2 .6  Technical data
Environmental conditions

Storage temperature max. 

−25°C … +70°C

Operating temperature max. 

-20°C … +50°C

Protection class 

IP67

Air and creeping distances acc. to IEC/EN 606641
- Overvoltage category 

3

- Degree of contamination 

3

Mechanical data

Design of the electrical connection
X1.1 - supply line 

plug connector M12, 5-pin

Locking force Fmax
- typical 

1500 N

- guaranteed 

1200 N

Fixing force 

30 N

Vertical offset 

± 2.5 mm

Lateral offset 

± 2.5 mm

Housing 

aluminum, hard-anodized

Solenoid 

aluminum, hard-anodized

Anchor plate 

steel, nickel-plated

Mechanical lifetime 

>107 switching operations

Shock resistance 

30 g/11 ms

Vibration resistance 

10-55 MHz

Dimensions
- Width 

24.4 mm

- Length 

257.0 mm

- Height 

22.2 mm

Anchor plate dimensions
- Width 

34.0 mm

- Length 

130.0 mm

- Height 

9.1 mm

Electrical data

Power supply UB 

Ue: 24 V DC − 15%/+ 10% (PELV acc. to 60204-1) 

Power consumption at UB 

7.2 W (300 mA at 24 V DC)

Switching frequency 

1 kHz

Rated insulation voltage Ui 

± 4 kV

Rated operating current Ie 

max. 40 mA

Utilization category 

DC-13

Idle current I0 

max. 300 mA

Electrical data inputs

Input
- Safety sensor 

IN 1, Pin 4

- Solenoid control 

IN 2, Pin 5

Rated operating voltage Ue 

−3 V … +5 V (low)

 

+15 V … +30 V (high)

Rated operating current Ie 

< 2 mA / 24 V

Electrical data diagnosis output

Diagnosis output 

OUT 1, pin 2

Function type 

sourcing, short circuit proof

Rated operating voltage UE 

−3 V … +5 V (low)

 

+15 V … +30 V (high)

Rated operating current IE 

< 2 mA / 24 V

Diagnosis function, OUT1
- Continuous signal 

input safety sensor OK and solenoid locked

- 1x flashing 

safety sensor switched on, solenoid not locked

- 2x flashing 

safety sensor not switched on, solenoid locked

- 3x flashing 

locking force of 900N not reached

- 4x flashing 

magnetic flux interrupted when throw open the door

- 5x flashing 

error magnetic flux measurement

Note 

The diagnosis output is not a safety-related output

Note:

 the power supply unit has to comply with rules and regulations for protective 

extra-low voltages (SELV, PELV). The inputs and outputs of the safety switch have 
to be equipped with a protective separation of voltage higher than 60 V AC.

3 .  Installation

3 .1  General installations notes

Always use support elements that are suitable for the expected ambient conditions. The 
installation may only be carried out by authorized skilled personnel.
The process guard locking can be installed on left- or right-hinged swing doors or sliding 
doors. Install the guard locking and the anchor plate parallel and opposite to each other. 
If a safety sensor, e.g. SAFIX, is installed and used for a safety function, observe the operating 
manual of the respective safety sensor.

Precautions during installation

Observe the following instructions to prevent injuries or damages to the device.

•  Check after the installation of the solenoid and the anchor plate if the surfaces are 

smooth and parallel to each other, in order to provide full contact when closing the door.

•  HOLDX L1 has to be installed as close as possible to the door handle. If there is a 

distance between the lock and the door handle, the door frame acts as a lever and the 
operating power necessary to open the lock is reduced. Furthermore, this can cause a 
rotation of the anchor plate towards the solenoid, which reduces the locking force of 
the lock significantly.

•  The locking force can be significantly reduced if the anchor plate and the foam cannot 

move, for this reason a full contact always has to be reached.

•  Connect the cable to the M12 plug only after the HOLDX L1 was installed on the safety door. 
•  Make sure that all safety functions were checked before commissioning of the system. 

Caution

The anchor plate must not be used as the only form of door hinge. In order 
to prevent damage to HOLDX L1, at least one additional door hinge has to 
be installed.
The surface of the magnet coil can get hot in continuous operation.

Installation of HOLDX L1 on a door

1. 

2. 

3. 

1. 

Place the HOLDX L1 in the required position and tighten the bolts. Close the door.

2. 

Attach the anchor plate together with the foam to the mounting bracket with the 
delivered bolts and washers.

3. 

Align the mounting bracket with the anchor plate to the same height as the HOLDX 
L1 and screw the mounting bracket on the door.

Mounting brackets are available as additional equipment.

Influence

Be aware that magnetic fields can delete data carriers and impact or destroy 
electronic or mechanic components, such as cardiac pacemakers. We are un-
aware of any negative influences for humans that originate from the magnetic 
fields of permanent magnets.
During direct contact to magnetic materials and systems, allergic reactions 
can arise (e.g. against ceramic and metallic materials as well as zinc, nickel 
and plastics).

Summary of Contents for HOLDX L1

Page 1: ...LDX L1 7 10 Declaration of Conformity 8 10 1EC conformity regulations 8 1 About This Document 2 1 1 Function 2 1 2 Safety instruction for the authorized skilled personnel 2 1 3 Symbols 2 1 4 Scope of...

Page 2: ...n if the safety notes and instructions regarding assembly installation operation and maintenance are followed 1 6 Attention Incorrect use Danger to persons or damages to parts of machines or installat...

Page 3: ...be carried out by authorized skilled personnel The process guard locking can be installed on left or right hinged swing doors or sliding doors Install the guard locking and the anchor plate parallel...

Page 4: ...d must never be used to control a safety application 5 Diagnostic functions 5 1 Diagnostic function of the process guard locking The process guard locking HOLDX L1 indicates the operating condition as...

Page 5: ...x 3x pulsing Locking force of 900 N not reached 2 6 Locking force not reached 24 V 24 V not activated off on off 4x pulsing Magnetic flux interrupted when throw open the door 1 7 Error force measureme...

Page 6: ...magnet coils or plug connectors must not be repaired and have to be replaced If the magnet coils are exposed to excessive loads additional safety measures may be necessary 7 Disassembly and Disposal...

Page 7: ...x 6 slots M12 8 pin M23 connector plug for connection cable XCONN P6 M12 M23 SP X 71 000 01 Y distributor XCONN Y1 M12 SP X 71 000 02 Jumper plug M12 8 pin Connector plug for unused slots XCONN A1 SP...

Page 8: ...available at the SSP website www safety products de 10 Declaration of Conformity 10 1 EC conformity regulations SSP Safety System Products GmbH Co KG Max Planck Stra e 21 78549 Spaichingen 49 7424 98...

Reviews: