8 .2  Pin assignment

Electrical data pin assignment

X1.1 

Supply line

A1 

Ue 

  1 BN 

brown

OUT 1 

diagnosis output 

 

WH 

white

A2 

GND 

  3 BU 

blue

IN 1 

input safety sensor 

BK 

black

IN 2 

input solenoid switch on 5 

GY 

gray

9 .  Equipment

9 .1  Equipment for HOLDX L1

Item

Denomination

Item no.

Passive junction XCONN

XCONN connection box
6 slots M12-8 pin
5 m connection cable 

XCONN P6-M12-5m

SP-X-71-000-00

XCONN connection box
6 slots M12-8 pin
10 m connection cable 

XCONN P6-M12-10m

SP-X-71-000-04

XCONN connection box
6 slots M12-8 pin
M23 connector plug for 
connection cable

XCONN P6-M12-M23

SP-X-71-000-01

Y distributor

XCONN Y1-M12

SP-X-71-000-02

Jumper plug M12-8 pin
Connector plug for unused slots

XCONN A1

SP-X-71-000-03

Safety sensors

RFID sensor SAFIX standard coding

SAFIX S1

SP-K-70-000-00

RFID sensor SAFIX custom coding

SAFIX I1

SP-K-70-000-01

RFID sensor SAFIX

SAFIX W1

SP-K-70-000-02

SAFIX standard actuator

SAFIX T3

SP-K-70-000-03

SAFIX flat actuator

SAFIX T4

SP-K-70-000-04

Safe Control Technology

Basic device for emergency off 
and safety door applications

S Series

SP-S-00-001-02

Basic device for emergency off 
and safety door applications

T series

SP-S-00-002-02

Safety PLC

MOSAIC M1

SP-R-11-000-00

Summary of Contents for HOLDX L1

Page 1: ...LDX L1 7 10 Declaration of Conformity 8 10 1EC conformity regulations 8 1 About This Document 2 1 1 Function 2 1 2 Safety instruction for the authorized skilled personnel 2 1 3 Symbols 2 1 4 Scope of...

Page 2: ...n if the safety notes and instructions regarding assembly installation operation and maintenance are followed 1 6 Attention Incorrect use Danger to persons or damages to parts of machines or installat...

Page 3: ...be carried out by authorized skilled personnel The process guard locking can be installed on left or right hinged swing doors or sliding doors Install the guard locking and the anchor plate parallel...

Page 4: ...d must never be used to control a safety application 5 Diagnostic functions 5 1 Diagnostic function of the process guard locking The process guard locking HOLDX L1 indicates the operating condition as...

Page 5: ...x 3x pulsing Locking force of 900 N not reached 2 6 Locking force not reached 24 V 24 V not activated off on off 4x pulsing Magnetic flux interrupted when throw open the door 1 7 Error force measureme...

Page 6: ...magnet coils or plug connectors must not be repaired and have to be replaced If the magnet coils are exposed to excessive loads additional safety measures may be necessary 7 Disassembly and Disposal...

Page 7: ...x 6 slots M12 8 pin M23 connector plug for connection cable XCONN P6 M12 M23 SP X 71 000 01 Y distributor XCONN Y1 M12 SP X 71 000 02 Jumper plug M12 8 pin Connector plug for unused slots XCONN A1 SP...

Page 8: ...available at the SSP website www safety products de 10 Declaration of Conformity 10 1 EC conformity regulations SSP Safety System Products GmbH Co KG Max Planck Stra e 21 78549 Spaichingen 49 7424 98...