0-97
CIRCUIT
REXTON 2007.09
6810-20
E. AIR QUALITY SYSTEM (AQS)
▶AQS operation
To change the AQS mode to Manual mode from AUTO mode, use the MODE switch or
the The AQS operates under air conditioner AUTO mode or when the AQS switch is
pressed under manual mode.It requires preheating time (for seconds) for operation and
the module and sensor are integrated. (However, it operates only when the DEF
(defroster) switch on the air conditioner switch panel is not pressed in.)
▶When driving out of polluted area
Remove the sensor and measure the resistance between terminal No. 5 and 6 on the
sensor connector. (standard: approx.
25°C,
2.2 kW)In addition, if the resistance
is extremely high or low, replace the sensor.
If the measured value is out of the specified range, replace the ambient temperature
sensor. If themeasured value is within the specified range, check as below.
Turn the ignition switch to ON position and measure the voltage to ambient
temperature sensor from theFATC controller connector. (standard: approx. 2 V at
25°C)
If the voltage value cannot be measured, check the circuit for open. If the measured
value is within thespecified range, replace the FATC controller.
-
-
-
-
▶AQS and air source selection switch
The AQS switch is integrated with the air source selection switch.
▶AUTO Mod
The air source is not changed when pressing the AQS and air source selection switch in
“AUTO”
mode. However,the indicator on the switch turned ON/OFF. In other words,
the air source cannot be changed to recirculationmode in AUTO mode by just pressing the
switch.To change the air source to recirculation mode in AUTO mode, get into Manual
mode first, then press the airsource selection switch.
▶Manual Mode
To change the AQS mode to Manual mode from AUTO mode, use the MODE switch or
the fan speed controldial. In Manual mode, the
“AUTO”
symbol on the display is
disappeared. When pressing the AQS and air sourceselection switch, the mode is
changed in order of AQS LED ON, AQS LED OFF (fresh air), and air source LEDON
(recirculation). The figure shows that the mode has been changed to the recirculation
mode from fresh air mode under AQSmode (AQS LED ON) after detecting the polluted
outside air.
Self diagnosis and preheating process during initial operation of A/C controller
(AUTO mode)
-
When the air conditioner controller is operated in AUTO mode during its initial
operation, the air sourceis changed to the recirculation mode and AQS LED comes
on.(This is the self diagnosis and preheating process for AQS.)
After completing the above process, the AQS LED is turned off and the air source is
automaticallychanged to the fresh air mode.
·
·
▶Components of AQS
Air Quality System (AQS) changes the air source selection to recirculation mode when
polluted air is detectedthrough AQS sensor. The air source selection returns back to fresh
air intake mode after a specified period orthe polluted air is disappeared.
▶AQS operation (AQS switch is pressed in): detecting the polluted outside air
When pressing the AQS switch, the LED on the AQS switch is turned on and the AQS
function is activated.
When the polluted outside air is detected, the AQS operates and converts the air
source to recirculationmode automatically. At this moment, the recirculation mode
indicator comes on in the display.
-
-
F. AQS OPERATION CIRCUIT
▶Ambient temperature sensor
If the polluted air is disappeared, the air source is automatically changed to the fresh
air mode and AQSLED stays on.
The air source is not changed when pressing the AQS and air source selection switch
in
“AUTO”
mode. To change the air source to recirculation mode in AUTO
mode, get into Manual mode first, then pressthe air source selection switch.
-
-
Measure the voltage value of AQS. (between connector terminal No. 3 and 4.)
If the measured voltage is out of 0.1 to 4.8 V, replace the AQS.
If the measured voltage is out of the specified range, replace the AQS. If it is within
the specified range, check as below.
Turn the ignition key to
“ON”
position.
Measure the voltage between terminal B9 and B15 on the air conditioner controller.
If the voltage value cannot be measured, check the circuit for open. If the measured
value is within thespecified range, replace the FATC controller.
-
-
-
-
-
-
▶AQS sensor
Summary of Contents for Rexton 2007
Page 2: ......
Page 6: ......
Page 8: ......
Page 11: ...0 5 CONNECTOR GROUND REXTON 2007 09 8201 00 GROUND SPLICE PACK ...
Page 13: ...0 7 CONNECTOR GROUND REXTON 2007 09 8201 00 S207 S301 CAN ...
Page 14: ...0 8 REXTON 2007 09 8201 00 CONNECTOR GROUND 5 CONNECTOR CIRCUIT C103 C105 C106 C101 C102 C104 ...
Page 15: ...0 9 CONNECTOR GROUND REXTON 2007 09 8201 00 C107 C109 C110 C111 C112 C114 C113 C108 ...
Page 16: ...0 10 REXTON 2007 09 8201 00 CONNECTOR GROUND C115 D27DT C115 D27DTP ...
Page 17: ...0 11 CONNECTOR GROUND REXTON 2007 09 8201 00 C115 GSL C204 C201 202 C203 ...
Page 18: ...0 12 REXTON 2007 09 8201 00 CONNECTOR GROUND C205 C206 C207 ...
Page 19: ...0 13 CONNECTOR GROUND REXTON 2007 09 8201 00 C209 C210 C211 Side A Bag C212 C213 C213A ...
Page 20: ...0 14 REXTON 2007 09 8201 00 CONNECTOR GROUND C214 C215 C217 Side A Bag C216 ...
Page 21: ...0 15 CONNECTOR GROUND REXTON 2007 09 8201 00 C218 C220 C219 ...
Page 24: ...0 18 REXTON 2007 09 8201 00 CONNECTOR GROUND C381 C371 C362 C361 ...
Page 26: ...0 20 REXTON 2007 09 8201 00 CONNECTOR GROUND C906 C907 C908 C903 C904 C905 ...
Page 27: ...0 21 CONNECTOR GROUND REXTON 2007 09 8201 00 WIRNING CONNECTOR ...
Page 28: ...0 22 REXTON 2007 09 8201 00 CONNECTOR GROUND UNIT CONNECTOR SWITCH CONNECTOR ...
Page 30: ...0 24 REXTON 2007 09 8210 00 CONNECTOR GROUND CONNECTOR 8210 00 W H ENGINE ROOM ...
Page 31: ...0 25 CONNECTOR GROUND REXTON 2007 09 8210 02 8210 02 W H MAIN ...
Page 32: ...0 26 REXTON 2007 09 8210 02 CONNECTOR GROUND ...
Page 33: ...0 27 CONNECTOR GROUND REXTON 2007 09 8210 03 8210 03 W H FLOOR ...
Page 34: ...0 28 REXTON 2007 09 8210 03 CONNECTOR GROUND ...
Page 35: ...0 29 CONNECTOR GROUND REXTON 2007 09 8210 09 8210 09 W H ROOF 8210 06 W H DRIVER DOOR ...
Page 36: ...0 30 REXTON 2007 09 8210 07 CONNECTOR GROUND 8210 07 W H PASSENGER DOOR 8210 08 W H RR DOOR ...
Page 37: ...0 31 CONNECTOR GROUND REXTON 2007 09 8210 10 8210 10 W H TAIL GATE ...
Page 38: ......
Page 40: ......
Page 43: ...0 5 POWER DISTRIBUTION REXTON 2007 09 8410 04 8410 04 I P FUSE BOX 1 FUSE BOX 2 POWER SUPPLY ...
Page 49: ...0 11 POWER DISTRIBUTION REXTON 2007 09 8410 04 8410 04 I P FUSE BOX CIRCUIT 1 F1 F5 2 F6 F10 ...
Page 50: ...0 12 REXTON 2007 09 8410 04 POWER DISTRIBUTION 3 F11 F15 4 F16 F22 ...
Page 51: ...0 13 POWER DISTRIBUTION REXTON 2007 09 8410 04 5 F23 F26 F32 6 F27 F31 ...
Page 52: ...0 14 REXTON 2007 09 8410 04 POWER DISTRIBUTION 7 F33 F36 ...
Page 55: ...0 17 POWER DISTRIBUTION REXTON 2007 09 8410 06 5 F PUMP RELAY INJ IGN RELAY SNR RELAY ...
Page 56: ......
Page 58: ......
Page 111: ...0 55 CIRCUIT REXTON 2007 09 8710 02 D RATED LOAD E INPUT SIGNALS ...
Page 147: ...0 91 CIRCUIT REXTON 2007 09 6910 01 ...
Page 148: ...0 92 REXTON 2007 09 6910 01 CIRCUIT 4 GENERAL TROUBLE CAUSES AND REMEDIES ...
Page 156: ......