SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 19 of 37
Step 6
Enable Century and ensure “Before Record “ is enabled.
Step 7
Configure the LAN Settings that the buffer should use. Remember to disable “Use
DHCP” when using a statis IP address.
Step 8
Under the TMS Settings configure the Buffer Name that will used to identify the
buffer on Udp Logger.
Step 9
Configure the Udp Logger IP or FQDN address in the TMS Server field.
Step 10
Set the Default Log Port to LAN Log.
Step 12
Set the LAN Log Mode to Client.
Step 13
Set the LAN Log IP Address to the PABX IP: E.g 192.168.0.221
Step 14
Set the LAN Log Remote IP to the PABX port: E.g 5003
Step 15
Under the TMS Settings. Set the TMS Server Address. E.g sstelecoms.dyndns.org
Step 16
Set the TMS server port. Default is 1122
Step 17
Click on “Upload Settings”
Step 18
Click on “Save & Reset”
Step 19
On UDP Logger add the Buffer ID to the contacts.