![SS Telecoms SS-77 uTMS User Manual Download Page 31](http://html.mh-extra.com/html/ss-telecoms/ss-77-utms/ss-77-utms_user-manual_1354338031.webp)
SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 31 of 37
SEND <nn>
Sends the number of records specified by <nn> on the MMI port that
was used to enter the command. The records will be preceded by a
line with the text:
DataBlock
Followed by the lesser of the number of requested records or that
actual number in the buffer. This is followed by:
TotalRecords x
Where ‘x’ is the actual number of records sent.
If the buffer is empty it sends the message “NO DATA<enter>”.
UPS <n>
Sets the packet size of the UDP packet to be used when logging
using UdpLog. <n> can be set from 0 to 7 giving the following values:
Value
Packet Size
Comment
0
200
Ensure that records are smaller !
1
300
2
400
3
600
4
800
5
1000
Default setting
6
1200
7
1400
Compatible with previous firmware
ULK <on/off>
Use Link status . Default is ‘ON’. Input can be Y/N, T/F, E/D, 1/0 or
ON/OFF. When enabled the buffer checks the physical link in relation
to stopping or starting the LAN functions. When switched ‘OFF’ the
Link Status is ignored and the LAN interface is started up just using
some timing delays.
PING <IP address or
name>
Sends 4 PING requests to the designated IP address or host-name.
ECC <on/off>
Enable Call Centre mode. Default is ‘OFF’. Input can be Y/N, T/F,
E/D, 1/0 or ON/OFF. When this option is enabled the buffer will output
call records on serial port 1.
Note that when Serial Port 2 is used for logging it is necessary to
ensure that Serial Port 1 is set up to use a baud rate the is the same
or higher than Serial Port 2.
MPW<password>
Sets the password. When a LAN connection comes in you will be
prompted for the new password.
Summary of Contents for SS-77 uTMS