SS-77 uTMS USER MANUAL
DOC. NO: SS-77 uTMS (REVISION 08)
Page 11 of 37
8.2. NG TOOL SETTINGS SCREEN
NG Tool Settings Screen
This screen is used to configure and upload the SS-77 settings
Setting
Description
Settings
Port Settings
Serial 1 Baud
Set the Serial Port 1 baud rate. This is the default MMI port. The
buffer can be accessed and programmed via this serial port. The
default baud rate is 115200
Serial 2 Baud
Set the Serial Port 2 baud rate. This is the default logging port for
collecting data. The PABX serial output would normally be
connected to this port. Default baud rate is 19200
Serial 2 Parity
Sets the number of data bits and parity format for Serial Port 2.
Through
Connection
The SS-77 has the ability to route the LAN socket #1 through the MMI serial port 1.
Amongst other things this allows LAN access to the serial port on a PABX.
Note: This mode of operation is only possible when LAN logging of the PABX is not
used.
Enable Trough
Connect
This will enable a through connection between the LAN socket
with the TCP port that is specified and the Serial Port 1of the SS-
77. Note: When enabling this feature the Serial MMI port 1 will be
set to Silent Mode.
LAN Local Port
Set the local port to listen for incoming connections. This can be
any number from 1 to 65524. Note that certain ports are
commonly used for tasks such as FTP, SMTP etc. so care needs
to be taken in choosing a suitable port number.