IMPORTANT SAFETY INFORMATION 

 
The  following  general  safety  precautions  have  to  be  observed  during  all  phases  of 
operation,  service,  and  the  repair  of  this  equipment.  Failure  to  comply  with  these 
precautions or with specific warnings in this manual violates safety standards of design, 
manufacture, and the intended use of this equipment. 
 

Do not operate in an explosive atmosphere! 

 
Do not operate this equipment in the presence of flammable gases or fumes. Operation of 
any  electrical  instrument  in  such  an  environment  constitutes  a definite  safety  hazard. 
Device should be never placed near or over a heat register or other source of heated air 
and it should not be installed or operated without proper ventilation.  

 
Mains AC 100-255V connection 

 

AC power is connected to the splitter full range power supply with worldwide use via 1.8m 
long  UniSchuko  cable  connected  to  the  splitter  via  PG.  Always  respect  the  markup  of  L 
and N on connectors for correct wiring of Line and Neutral.  
 

DMX connection 

 

DMX connectors are located on both sides of the splitter board. These are separated to 
two groups. First group is wired in ratio 1:1 and marked as DMX input and DMX thru. This 
line is not optically isolated and when the device is last in line, it should be terminated by 
the  termination  resistor  of  120ohm  wired  between  pins  2  and  3  of  the  DMX  thru 
connector. 
 
The  other  group  consists  of  4-way  optically  isolated  lines  marked  with  letters  A-D.  Each 
line has a separate power supply, line driver and the indication of signals D+, D- on both 
signal lines. These LEDs are active when splitter is retransmitting DMX signal and there is 
no short circuit between data lines. 
 
In case of short circuit between data pins D+/D- and the CMN pin, the LED connected to 
the data line is off. 

 

 