7
USING THE H20 WELDER
Start Up:
1.
Plug the electric cord to the appropriate 110V 220V electrical outlet.
2.
Locate the chrome cap on top of the cabinet. This is the water tank
inlet spout. Turn the toggle switch to the REFILL position. The
greenish yellow minimum light will go on.
a.
Pour the entire contents of caustic “B” electrolyte solution into
the water tank using the large funnel.
CAUTION:
The electrolyte solution contains a strong caustic. If any
contact occurs with skin, wash immediately with water. Avoid
contact with eyes.
b.
Fill the empty bottle approximately 1 2/3 full of distilled water.
Carefully pour into the ware tank and
STOP IMMEDIATELY
when the
RED
light goes on. The water tank is full. Now screw
the water tank cap on tight.
NOTE: As you start pouring distilled water into the tank, the
minimum light will go off. Now both lights will be off until the red
maximum light goes on.
3.
Find the booster tank located in the front of the cabinet. Unscrew
the T-handle to remove the booster tank. Carefully pour methyl
alcohol (also known as Methanol) into the tank, use the small funnel
so that fluid does not enter the center section of the tank.
Summary of Contents for 350