background image

Model SRV710W Series 
Operating and Service Manual 
Part No. MAN710W_210602 

 

Page 3 of 16 

 
 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

     

  

Copyright 2021

 

S

Instruments, Inc. 

 

PACKING CHECKLIST - Model SRV710W 

Zoological Scale System 

 

 
 

 

DESCRIPTION 

QUANTITY 

 

PLATFORM SCALE 

1 ea 

 

PACK OF SIX (6) “AA” BATTERIES 

1 ea 

 

CALIBRATION CERTIFICATE 

1 ea 

 

WARRANTY CARD 

1 ea 

 

TABLET AND CASE 

1 ea 

 

MANUAL 

1 ea 

Summary of Contents for SRV710W Series

Page 1: ... 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc S by SR Instruments Inc Operating and Service Manual Zoological Scale System App Enabled Wireless Model SRV710W ...

Page 2: ...DEL SRV710W 3 ASSEMBLY 4 REPLACEMENT PARTS AND ACCESSORIES 4 SYSTEM DESCRIPTION AND INTENDED USE 5 STORAGE AND TRANSPORTATION 5 CLEANING AND DISINFECTING 6 SPECIFICATIONS 7 BUTTON FUNCTIONS 8 BASIC SYSTEM OPERATION 8 SR SCALES APP 9 BATTERY REPLACEMENT 10 THEORY OF OPERATION 11 CALIBRATION 12 TROUBLESHOOTING 13 WARRANTY 14 NOTES 15 TABLE OF FIGURES Figure 1 Battery Compartment 4 Figure 2 LB KG Mod...

Page 3: ...Y 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc PACKING CHECKLIST Model SRV710W Zoological Scale System DESCRIPTION QUANTITY PLATFORM SCALE 1 ea PACK OF SIX 6 AA BATTERIES 1 ea CALIBRATION CERTIFICATE 1 ea WARRANTY CARD 1 ea TABLET AND CASE 1 ea MANUAL 1 ea ...

Page 4: ... missing or damaged parts call the Service Hotline at 1 800 654 6360 STEP 2 Place the Platform upside down on the floor and remove the cover on the Battery Compartment STEP 3 Install six 6 AA cell batteries and select desired units of weight to be displayed with LB KG switch according to BATTERY REPLACEMENT instructions STEP 4 Turn platform right side up and press the DISPLAY button to confirm dis...

Page 5: ...splayed with a displayed resolution of 0 2 pounds or 0 1 kilograms The SRV710W Zoological Scale is equipped with a Bluetooth wireless module By waking the scale up with the weigh button the wireless feature is turned on Then use the free SR Scales app Google Play store to connect with the scale to allow for remote wireless operation INTENDED USE The SRV710W Zoological Scale is designed for use wit...

Page 6: ...a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectants Disinfectant solutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact surfaces After disinfecting use a soft cloth dampened with cl...

Page 7: ...BLUETOOTH ON TIME 5 minutes from last button press AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA cell batteries CALIBRATION Calibration is traceable to NIST standards OPERATING CONDITIONS Normal operating conditions for this product Ambient Temperature Range 40 F to 95 F 5 C to 35 C Relative Humidity Range 0 to 85 Avoid exposure to high pressure water or steam TRANSPORTATION AND STORAGE...

Page 8: ...rside of the scale Select the mode for weighing with this Toggle Button Figure 2 LB KG Mode Pushbutton Switch BASIC SYSTEM OPERATION Ensure that the scale is free and clear of any obstructions before operating Press the DISPLAY button and hold it for 2 3 seconds The display will read 0 0 and be ready for weighing When a mat or pad is to be used on the scale platform the weight of the pad must be t...

Page 9: ...eless operation Use your Android device to display weight and control the SRV710W scale functions Figure 3 Ensure your remote display indicates CONNECTED before use The WEIGH button will display weight in pounds or kilograms as selected The Held Wt button allows access to the last stable weight that was achieved The ZERO button is used to zero the system The KILOS button allows weight data to be v...

Page 10: ...lacement is needed an indicator will appear on the display STEP 1 Turn the platform over and remove the four screws on the Battery Cover Figure 4 STEP 2 Remove and replace the six 6 AA cell batteries STEP 3 Press the DISPLAY button to confirm display is working Verify that the desired units of weight LB KG are active STEP 4 Replace the screws in the Battery Cover NOTE TIGHTEN SCREWS ONLY UNTIL RUB...

Page 11: ... four strain gauges mounted in a full Wheatstone bridge configuration These bridges convert the physical movement of the force cell due to the applied mass on the system into minute changes in electrical resistance These changes in resistance produce a voltage difference across the Wheatstone bridge which is amplified by the operational amplifier The amplifier is configured to current sum the outp...

Page 12: ...selected weight from Step 1 Use the DISPLAY button to select digit positions and use button S4 to change the value STEP 7 When finished the display will read SAVE Press the DISPLAY button to save or press button S4 then DISPLAY to QUIT STEP 8 Press S4 to scroll to the menu option 2 PT and press the DISPLAY button Figure 5 Calibration Buttons STEP 9 Ensure nothing is in contact with the platform th...

Page 13: ...ecurely tighten screws NOTE TIGHTEN SCREWS ONLY UNTIL RUBBER SEAL STARTS TO COMPRESS STEP 14 Press and hold the DISPLAY button to zero the platform When the display indicates 0 0 place the calibrated weight on the scale again and check against the weight displayed If the weight is not correct recalibrate If calibration cannot be accomplished call the Service Department TROUBLESHOOTING SYMPTOM REAS...

Page 14: ...es on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery...

Page 15: ...g and Service Manual Part No MAN710W_210602 Page 15 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc NOTES ...

Page 16: ...MAN710W_210602 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc S By S Instruments Inc Precision Technology in Perfect Balance ...