CLEANING and DISINFECTING 

CLEANING 

To clean the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with water and mild detergent to clean scale surfaces. 

 

Wipe surface with clean soft cloth dampened with water and then dry with clean soft cloth.  

 

Do  not  use  abrasive  materials  to  clean  scale  surface  to  prevent  damage  to  the  surface 
finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

DISINFECTION 

To disinfect the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth.  Cloth 

cannot  be  dripping  wet.    Follow  manufacturer’s  instruction  on  the  proper  use  of 
commercially available disinfectants.  

 

Disinfectant solutions with 1% sodium hypochlorite or 70% isopropyl alcohol are suitable 
for display / user interface and other scale contact surfaces. 

 

After  disinfecting,  use  a  soft  cloth  dampened  with  clean  water  and  dry  with  a  soft  clean 
cloth to prevent buildup of material on scale finish. 

 

Do  not  use  abrasive  material  to  disinfect  /  clean  scale  surfaces  to  prevent  damage  to  the 
surface finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

WARNING:

 

DO  NOT  SPRAY  CLEANING  SOLUTION  OR  LIQUIDS  DIRECTLY 
ON SURFACES TO BE CLEANED

  

 

WARNING:  EXPOSURE  TO  EXCESSIVE  LIQUID  WILL  DAMAGE  USER 

INTERFACE KEYPAD 

 
WARNING:

 

DO  NOT 

USE  PRESSURIZED  WATER  OR  STEAM.    THE  SCALE 

SYSTEM CONTAINS ELECTRONIC COMPONENTS THAT MAY BE 
ADVERSELY  AFFECTED  BY  EXPOSURE  TO  SUCH  AN 
ENVIRONMENT. 

 

STORAGE 

 

Platform should be stored in the upright position when not in use to prevent a trip and fall hazard. 

If storing this equipment for periods longer than three (3) months store in the upright position to prevent 
damage  to  the  hydraulic  cylinders.  To  maintain  proper  operation  of  this  instrumentation,  storage  and 
transport  conditions  should  not  vary  outside  the  following  conditions:  Relative  Humidity  0%  to  85%, 
Ambient Temperature 

14

F to 122

F

 (-10

C to +50

C). 

Summary of Contents for SR Scales SR7020i

Page 1: ...ICROBAN_200520 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by...

Page 2: ...INSTALLATION 3 REPLACEMENT PARTS AND ACCESSORIES 6 SYSTEM DESCRIPTION AND INTENDED USE 6 MICROBAN ANTIMICROBIAL PROTECTION 6 MAINTENANCE AND CLEANING ERROR BOOKMARK NOT DEFINED STORAGE 7 SPECIFICATION...

Page 3: ...t location for the scale by considering these recommendations Have free wall hallway space to roll equipment onto the scale from either side Platform extends 42 into the hallway when folded down Hallw...

Page 4: ...ure 2 NOTE The wall mounting bracket does not need to be centered on the crossbar but must be located between the bumpers STEP 5 For stud walls use a stud finder and locate any studs in the mounting a...

Page 5: ...head screws long enough to anchor into the wall or the concrete anchors NOTE The screws need to be a flat head type screw so there is adequate clearance for the scale frame to slide into the wall bra...

Page 6: ...atform Scale system has a 38 x 58 96 5 cm x 147 3 cm platform weighing surface The scale system has a programmable Automatic Power Down APD for adjusting scale on time INTENDED USE The SR7020i Wall Mo...

Page 7: ...olutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact surfaces After disinfecting use a soft cloth dampened with clean water and d...

Page 8: ...e button operation after platform is left down AUTO POWER DOWN Adjustable between 30 to 300 seconds AVERAGING Automatic digital filter POWER SUPPLY Medical Grade AC Power Supply CALIBRATION Calibratio...

Page 9: ...Press to recall the last stored weight The stored weight will be erased when the scale is zero or another stable weight is stored BMI Press to calculate BMI When the BMI is pressed the default value H...

Page 10: ...etting time and date BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Scale will auto zero when the platform is first lowered Make sure the scale is free and clear of any obstructions When platform is left...

Page 11: ...he amplifier is configured to current sum the output of each cell with potentiometers serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiomete...

Page 12: ...DO NOT USE barbells or uncalibrated weights STEP 2 Zero the scale by pressing and holding the left ZERO button STEP 3 Place the calibrated weight on the scale Wait for scale to stabilize note scale re...

Page 13: ...abort any changes STEP 4 Press the MENU button until HALF 500 0Lb is displayed NOTE The Half Scale value is a value between zero and the Full Scale values It is usually close to half the Full Scale v...

Page 14: ...WEIGH button or disconnect power Wait five seconds then re connect the power and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure th...

Page 15: ...r liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In...

Page 16: ...No MAN7020I_MICROBAN_200520 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstr...

Reviews: