SR Instruments SR Scales SR7005i Operating And Service Manual Download Page 7

Model SR7005

i

 Wall Mount In-Room Mini Scale 

Operating and Service Manual 
Part No. MAN7005i_200520 

Page 7 of 16 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

       Copyright 2020

 

S

Instruments, Inc. 

CLEANING and DISINFECTING 

CLEANING 

To clean the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with water and mild detergent to clean scale surfaces. 

 

Wipe surface with clean soft cloth dampened with water and then dry with clean soft cloth.  

 

Do  not  use  abrasive  materials  to  clean  scale  surface  to  prevent  damage  to  the  surface 
finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

DISINFECTION 

To disinfect the display / user interface and other scale contact areas:  

 

Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth. Cloth 
cannot  be  dripping  wet.  Follow  manufacturer’s  instruction  on  the  proper  use  of 
commercially available disinfectants. 

 

Disinfectant solutions with 1% sodium hypochlorite or 70% isopropyl alcohol are suitable 
for display / user interface and other scale contact surfaces. 

 

After  disinfecting,  use  a  soft  cloth  dampened  with  clean  water  and  dry  with  a  soft  clean 
cloth to prevent buildup of material on scale finish. 

 

Do  not  use  abrasive  material  to  disinfect  /  clean  scale  surfaces  to  prevent  damage  to  the 
surface finish. 

 

Do not spray liquid directly onto scale surfaces. Use only a damp cloth. 

 

WARNING:

 

DO  NOT  SPRAY  CLEANING  SOLUTION  OR  LIQUIDS  DIRECTLY 
ON SURFACES TO BE CLEANED

 

WARNING:  EXPOSURE  TO  EXCESSIVE  LIQUID  WILL  DAMAGE  USER 

INTERFACE KEYPAD. 

 

WARNING:

 

DO  NOT 

USE  PRESSURIZED  WATER  OR  STEAM.  THE  SCALE 

SYSTEM CONTAINS ELECTRONIC COMPONENTS THAT MAY BE 

ADVERSELY  AFFECTED  BY  EXPOSURE  TO  SUCH  AN 

ENVIRONMENT. 

 

STORAGE 

 

Platform should be stored in the upright position when not in use to prevent a trip and fall hazard. 

If  storing  this  equipment  for  periods  longer  than  three  (3)  months,  remove  the  batteries  and  store  in  the 
upright  position  to  prevent  damage  to  the  hydraulic  cylinders.  To  maintain  proper  operation  of  this 
instrumentation, storage and transport conditions should not vary outside the following conditions:  

Relative Humidity 0% to 85%, Ambient Temperature 14

F to 122

F (-10

C to +50

C). 

Summary of Contents for SR Scales SR7005i

Page 1: ...00520 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S Instru...

Page 2: ...F CONTENTS PACKING CHECKLIST 3 INSTALLATION 3 MICROBAN ANTIMICROBIAL PROTECTION 5 SYSTEM DESCRIPTION AND INTENDED USE 6 CLEANING AND DISINFECTING 7 STORAGE 7 SPECIFICATIONS 8 BUTTON FUNCTIONS 9 BASIC...

Page 3: ...tends 23 into the room hallway when folded down Hallway must be wide enough to allow suitable access and egress for personnel using the hallway If using the AC power supply a wall outlet must be locat...

Page 4: ...walls use a stud finder and locate any studs in the mounting area STEP b Measure up from the floor 27 5 8 and make a mark at a stud location This will be the location of bottom edge of the wall mount...

Page 5: ...ons STEP b For stud wall mounting locations without a stud use a screwdriver to drive the provided self drilling wall anchors into the wall It is not recommended to use a power drill to set the wall a...

Page 6: ...t s weight is displayed on a 16 character dot matrix LCD w LED backlight The weight data may be viewed either in pounds or kilograms with a displayed resolution of 0 1 for each The SR7005i Wall Mount...

Page 7: ...sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact surfaces After disinfecting use a soft cloth dampened with clean water and dry with a soft...

Page 8: ...AUTO POWER DOWN Adjustable between 30 to 300 seconds AVERAGING Automatic digital filter POWER SUPPLY Six 6 C cell batteries Replace battery indicator on Display Medical grade AC power supply CALIBRAT...

Page 9: ...last stored weight The stored weight will be erased when the scale is zeroed or another stable weight is stored BMI Press to calculate BMI When the BMI is pressed the default value HT 65 in or HT 165...

Page 10: ...ng time and date BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Scale will auto zero when the platform is first lowered Make sure the scale is free and clear of any obstructions When platform is left down...

Page 11: ...lied mass on the system into minute changes in electrical resistance These changes in resistance produce a voltage difference across the Wheatstone bridge which is amplified by the operational amplifi...

Page 12: ...NIST NOTE DO NOT USE barbells or uncalibrated weights STEP 2 Zero the scale by pressing and holding the ZERO button STEP 3 Place the calibrated weights on the scale Wait for scale to stabilize note sc...

Page 13: ...button until HALF 250 0 lb is displayed Set the HALF value to the actual quantity of calibrated weight being used for Half Scale Use the UP arrow button to select the digit and the DOWN arrow button t...

Page 14: ...attery Wait five seconds then re install battery and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure the membrane switch label is c...

Page 15: ...liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In n...

Page 16: ...al Part No MAN7005i_200520 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstrum...

Reviews: