System Information 

This display indicates the internal clock's current time and the Power Outage. Each time the Herpstat 4 is 

powered on it increments the Power Outage Monitor.  To reset the monitor to zero press the + button. 

 

 

 

This display indicates the current time schedule each output is adhering to.  If the NiteCycle is disabled on the 

output it will always show Day Cycle.  If an output's mode is set to disabled then it will also show disabled here. 

 

 

 

This display will only be available if one of the humidity modes is enabled.  If the mode is set to Humidity 

Scheduled or Hybrid then pressing the Plus button will schedule a humidity session once the internal clock gets 

to the following minute.  When the mode is set to Humidity Sensed then pressing the Plus button will power on 

the output.  This type of forced session has an automatic timeout but should be canceled by the user and not 

left unattended.  After initiating a forced humidity session pressing the Plus button a second time will end/cancel 

the session.   

 

 

 

This display will only be available if one of the lighting modes is enabled.  If the Plus button is pressed it will 

turn on the outputs set to lighting.  Pressing the Plus button a second time will return the lights to their previous 

state. 

 

 

Getting the most out of your Herpstat 4 

(Troubleshooting) 

 

When setting up a new environment allow a minimum of one hour for the temperature to stabilize.  Keep in 

mind that all items in the enclosure are warming up including the enclosure walls.  Probe placement will require 

experimentation to achieve proper temperature regulation.   

 

If after an hour of initial regulation the temperature does not reach within a degree of the target temperature 

this is an indication of insufficient heating source.  Add an additional heat device to the enclosure or switch to a 

higher wattage heat device.  

Do not exceed 400 watts per output.

 

 

The Herpstat 4 has standard 5mmx20mm fuses with a rating of 3.5 amps.  Should it appear that one of the 

outputs is no longer providing power the fuse for that output may need to be replaced.  To do this unplug all 

cables from the back of the unit including power.  Remove the two screws at the bottom of the unit.  Gently lift 

and remove the top half of the case.  On the circuit board there are 4 fuse holders each in front of the 

corresponding outlet.  Some models may have a clear case over the top of the fuse holder.  The clear case 

typically lifts straight off.  Remove the fuse from the fuse clips and replace with a new fuse.  Do not use any 

fuse with a rating higher than 3.5 amps.  Reassemble the unit and test that the outputs are working properly 

before putting back into service.  

 

Should the device not work as expected it's possible one of the menu settings was set incorrectly.  It may be 

easier to reset the device to its factory default settings than to figure out which setting is causing the issue.  To 

do this hold down the Plus button while applying power to the Herpstat.  Once the display reads Loading 

Defaults release the button. 

 

Do not use aluminum tape on the probe tip.

  This will cause false readings and poor regulation.   

 

If possible route the probe wires so that they are not in direct contact with the 120vac cables going to the 

heating devices.  Preferably leave at least a few inches between the probe wires and the AC lines to avoid cross 

talk/electrical interference issues. 

 

 

 

 

 

Getting Help 

 

Questions or comments can be e-mailed to: 

[email protected]

 

To purchase accessories please visit us on the web at: 

http://www.spyderrobotics.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Year Limited Warranty 

 

Spyder Robotics warrants this product to be free from defects in workmanship and material for a period of one 

year from the date of purchase by the original purchaser.  The warranty period shall not extend beyond 3 years 

from the date Spyder Robotics shipped the product.  During this warranty period Spyder Robotics will repair or 

replace, at its option, any component parts that in its opinion prove to be defective.  Replacement parts may be 

new or serviceable used parts at Spyder Robotics option, of equal or better quality to those being replaced.  This 

warranty does not extend and shall not apply to products that have been subjected to misuse, neglect, accident, 

or improper installation. 

 

THIS LIMITED WARRANTY AND REMEDY ARE EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES 

EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MECHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL SPYDER ROBOTICS BE LIABLE FOR LOST 

PROFITS, LOSS OF GOODWILL, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES.   

 

If you return your product to Spyder Robotics for warranty service, proof of purchase may be required.  A 

Return Material Authorization (RMA) number must be obtained prior to the return.  Spyder Robotics is not 

responsible for material returned without the RMA number clearly printed on the outside of the shipping 

container.  To request an RMA number, contact Spyder Robotics with the description of failure, serial number of 

device, and date of purchase via e-mail at 

[email protected]

.   

 

 

 

 

©2011 Spyder Robotics 

 

 

 

 

 

manual-HS213 

http://www.spyderrobotics.com

 

 

 

 

 

 

5.5.2015 

 

 

 

 

Summary of Contents for Herpstat 4

Page 1: ...tput High Low temperature tracking helps monitor heating system and enclosure efficiency Individually selectable High Low temperature threshold alarms Precision temperature sensors with an internal resolution of 1125 F and are accurate to 9 F Display and setting in tenths of a degree Security Passcode option deters vandals All settings are retained in memory even if power is lost Power Outage dete...

Page 2: ...djust the settings Grounded outlets 3 prong plugs were added to accommodate more types of heating devices Basking assist feature added supports basking lights as a heat source Typically a proportional thermostat reduces power when the temperature is close to the target temp and turns off when the target temperature is breached This causes a strobing effect when using basking lights Basking assist ...

Page 3: ...rol continued DayTemp The DayTemp setting is the temperature the device will try to maintain during the Day Cycle If the Nite Cycle is disabled then the Day Temp setting will be used for the full 24hrs SnsrAdj The SnsrAdj Sensor Adjust setting is used to alter the temperature read by the temperature probe to match other equipment Note The sensor used in the Herpstat Probes are typically more accur...

Page 4: ...ntinued RH Note Only available in Humidity Sensed or Humidity Hybrid modes This setting adjusts the highest level of relative humidity Once this amount has been breached the power will shut off to the output Schedule Menu Enter this menu to set the scheduled times to activate a humidity session Note Only available in Humidity Scheduled or Humidity Hybrid modes In this menu use the Plus and Minus b...

Page 5: ... an error condition This also controls the built in safety relay Once the error condition is corrected the device will return to normal operations Options INDIVIDUAL OUTPUTS Excludes High Low This option is the default setting and does not enable the built in safety relay During an error condition it turns off the output that has the error High Low alarms will not shut off the output INDIVIDUAL OU...

Page 6: ...se clips and replace with a new fuse Do not use any fuse with a rating higher than 3 5 amps Reassemble the unit and test that the outputs are working properly before putting back into service Should the device not work as expected it s possible one of the menu settings was set incorrectly It may be easier to reset the device to its factory default settings than to figure out which setting is causi...

Reviews: