Safety 

Precautions

 Page 6 

Compliance with national gas regulations shall be observed.

Keep ventilation openings clear of obstruction.

The appliance shall be stored so as to prevent mechanical damage from occurring.

A warning that the appliance shall be stored in a well-ventilated area where the room size corre-

sponds to the room area as specified for operation.

Any person who is involved with working on or breaking into a refrigerant circuit should hold a 

current valid certificate from an industry-accredited assessment authority, which authorises their 

competence to handle refrigerants safely in accordance with an industry recognised assessment 

specification.

Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance 

and repair requiring the assistance of other skilled personnel shall be carried out under the super-

vision of the person competent in the use of flammable refrigerants.

AVERTISSEMENT 

Ne pas utiliser de produits permettant d’accélérer le dégel ou de produits de nettoyage autres que 

ceux recommandés par le fabricant. 

L’appareil doit être entreposé dans un endroit sans source d’allumage fonctionnant en continu (par 

exemple : flamme nue, appareil au gaz en marche ou radiateur électrique en marche). 

Ne pas percer ni bruler. 

Attention : les frigorigènes peuvent être inodores.

Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid 

any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintai-

ning or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, 

shall not discharge to air directly.

Don't use near any open fire or device like switch which may generate spark/arcing shall be around 

air conditioner to avoid causing ignition of the flammable refrigerant used. 

Please follow the instruction carefully to store or maintain the air conditioner to prevent 

mechanical damage from occurring.

Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid 

any hazard.For specific information on the type of gas and the amount,please refer to the relevant 

label on the unit itself.

The appliance shall be stored in a room without continuously operating open flames (for example an 

operating gas appliance) and ignition sources (for example an operating electric heater).

For R32 refrigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than 43.06 sq.ft  .
Appliance shall not be installed in an unvertilated space, if that space is smaller than 43.06 sq.ft  .

Summary of Contents for WA-S7000E

Page 1: ...on Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference PORTABLE AIR CONDITIONER WA S7000E...

Page 2: ...ation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Instal...

Page 3: ...is grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your un...

Page 4: ...ould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the su...

Page 5: ...capes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to clean or come into contact with the unit Do...

Page 6: ...reil au gaz en marche ou radiateur lectrique en marche Ne pas percer ni bruler Attention les frigorig nes peuvent tre inodores Please follow the instruction carefully to handle install clear service t...

Page 7: ...side the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area A...

Page 8: ...uit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be cor...

Page 9: ...e following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may...

Page 10: ...Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment i...

Page 11: ...ted weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in...

Page 12: ...The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diameter 5 9inch Length 59inch Diameter 5 12inch Length 59inch The Energy rating and noise information for unit with 3...

Page 13: ...square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat...

Page 14: ...Hose Drain Hose 1 pc Window Slider Adaptor O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and Battery on...

Page 15: ...ders once they are adjusted to the Proper length Window slider A Window slider B Bolt Window slider A Window slider B Window slider C Bolts Step Two Install the Exhaust hose assembly to the unit MODEL...

Page 16: ...sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive type 3 Cut the non adhesive foam seal C...

Page 17: ...actual shape shall prevail NOTE Cover the hole using the adaptor cap when not in use max 120cm or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B Or 5 Insert t...

Page 18: ...error select models only E4 Display panel communication error EC Refrigerant leakage detection malfunction select models only Shows protection code P1 Bottom tray is full Connect the drain hose and d...

Page 19: ...nd UP buttons at the same time for 3 seconds to turn off Wireless function and the LED DISPLAY shows OF for 3 seconds press MODE button and UP to turn on Wireless function and the LED DISPLAY shows On...

Page 20: ...sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Place the end of the hose into the drain andmake su...

Page 21: ...e unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the app...

Page 22: ...urn off the unit and clean the filter according to instructions Call a service technician to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are c...

Page 23: ...TANT NOTE REMOTE CONTROLLER Thank you for purchasing our air conditioner Please read this manual carefully before operating your new air conditioning unit Make sure to save this manual for future refe...

Page 24: ...d Functions sections of this manual for a detailed description of how to use your air conditioner SPECIAL NOTE Button designs on your unit may differ slightly from the example shown If the indoor unit...

Page 25: ...FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may...

Page 26: ...SPEED Selects fan speeds in the following order AUTO LOW HIGH TEMP Decreases temperate in 1 F increments Min temperature is 62 F TIMER ON Sets timer to turn unit on see How to Use Basic Functions for...

Page 27: ...Displayed when remote controller is ON Low speed NO display Medium speed some units High speed Auto fan speed Displayed when TIMER ON time is set Displayed when TIMER OFF time is set Indicated all th...

Page 28: ...OFF Select DRY mode Set your desired temperature Turn on the air conditioner FAN Mode MODE ON OFF Select FAN mode Turn on the air conditioner Select COOL HEAT mode Set the temperature Turn on the air...

Page 29: ...2 Cancel either function by setting its timer to 0 0h Point remote to unit and wait 1sec the TIMER ON will be activated Press TIMER OFF button to initiate the OFF time sequence Point remote to unit a...

Page 30: ...is used to decrease energy use while you sleep and don t need the same temperature settings to stay comfortable This function can only be activated via remote control The sleep function is not availab...

Page 31: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CR2712 RG51F H 1...

Page 32: ...t parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not in...

Reviews: