background image

© SprayTECH.  All rights reserved. 

3

English

table of contents

Safety ......................................................................................... 2

 

Grounding Instructions ........................................................ 2

Service ....................................................................................... 2

Introduction ............................................................................... 3

using an hvLP Spray System ................................................. 3

 

Setup ................................................................................... 3

 

Dual Filtration System ......................................................... 3

Maintenance .............................................................................. 4

 

Cleaning/Replacing Filters .................................................. 4

 

Cleaning the Air Hoses........................................................ 4

wiring Diagram ......................................................................... 4

troubleshooting ....................................................................... 5

Parts List ........................................................................... 14–15

Français ..................................................................................... 6

español.................................................................................... 10

warranty .................................................................................. 16

Introduction

This High Volume/Low Pressure (HVLP) spray system is 

designed for applying coatings to surfaces that can be sprayed 

faster than brushing or rolling and are too small for traditional 

airless sprayers.  Components of this system include a power 

switch, a power cord, a filter warning light, a circuit breaker 

switch, a dual filtration system, a cup holder, an air hose, and an 

air outlet.

Cup Holder

Circuit

Breaker

Switch

Filter 

Warning

Light

Power Switch

Power Cord

Filter

Filter (in end

of filter can)

Air Hose

Air Outlet

With this HVLP spray system, you can achieve the highest quality 

professional finish possible with little or no preparation or setup 

time.  Please review all the information contained in this manual 

before operating the system.

using an hvLP Spray System

Refer to the following information to operate and understand your 

HVLP spray system.

Setup 

Use the following procedure to set up your HVLP spray system 

for operation.

  1.  Plug the turbine power cord into a grounded, 3-slot 

receptacle.

keep the turbine at the maximum possible distance 

from the spray area to safeguard against explosion 

or fire that may be caused by sparking electrical 

parts.

  2.  Prepare your spray gun for operation.  Refer to your spray 

gun manual for material preparation, setup, and spraying 

information.

  3.  Attach the air hose to the air outlet on the turbine.

  4.  Attach the air hose to the air inlet on your spray gun.

  5.  Turn on the turbine and begin spraying.

Dual Filtration System

The turbine has two different air filters— one for atomizing air 

and one for cooling air.  The atomizing air filter is a two-stage, 

fine mesh filter designed to trap particles that may damage your 

finish. The atomizing air is discharged through the nozzle of the 

spray gun where it atomizes the coating material.  The cooling air 

filter is a coarse mesh filter designed to allow the proper amount 

of air flow through the turbine for cooling purposes.  Cooling air 

is exhausted through the cooling air discharge on the front of the 

turbine.

Cooling Air Discharge

Cooling Air

Intake

Atomizing Air

Intake

Atomizing Air

Discharge

Filter warning System

The filter warning system on your turbine consists of a red filter  

warning light on the front control panel and an air flow switch 

inside the turbine.  When the air flow switch does not detect the 

appropriate amount of air flowing through the turbine, the filter 

warning light will come on to indicate that it is time to clean or 

change the filters.

 NOTE:  The filter warning system does not shut down the 

turbine.

IMPoRtant:  clean filters regularly.  clogged filters can 

cause excessive heat and possibly damage the turbine.

Summary of Contents for CAPspray CS9960

Page 1: ...propietario 0708 SprayTECH All Rights Reserved Form No 0277999B CAPSpray 1770 Fernbrook Lane Minneapolis MN 55447 Technical Assistance Order Entry Fax Technical Assistance Fax Order Entry 1 800 526 53...

Page 2: ...warnings HAZARD HAZARDOUS VAPORS Paints solvents insecticides and other materials can be harmful if inhaled or come in contact with the body Vapors can cause severe nausea fainting or poisoning PREVEN...

Page 3: ...le distance from the spray area to safeguard against explosion or fire that may be caused by sparking electrical parts 2 Prepare your spray gun for operation Refer to your spray gun manual for materia...

Page 4: ...to its corresponding filter can NOTE The two stage atomizing air filter must be placed in the filter can labeled 2 Stage Filter with the green side facing the turbine After several cleanings it may be...

Page 5: ...Check the power supply 2 Check and replace the fuse 3 Have the brushes replaced at an authorized CAPSpray service center 1 Have the brushes replaced at an authorized CAPSpray service center 2 Replace...

Page 6: ...ource d tincelles provoqu es par l lectricit statique Ne jamais utiliser une couverture en plastique pour fermer une zone d pandage ni utiliser des toiles de protection en plastique lors de la pulv ri...

Page 7: ...ne mise la terre Maintenir la turbine aussi loign e que possible de la zone de vaporisation de mani re viter tout incendie ou explosion provoqu par les pi ces produisant des tincelles 2 Pr parer faire...

Page 8: ...ure laque 3 Remonter chaque filtre dans son carter correspondant NOTA Le filtre d atomisation deux tages doit tre mont dans le carter de filtre portant l tiquette 2 Stage Filter Filtre deux tages avec...

Page 9: ...filtres 1 Nettoyer ou remplacer les filtres 1 V rifier l alimentation lectrique 2 V rifier et remplacer le fusible si n cessaire 3 Faire remplacer les balais par un centre de service agr CAPSpray 1 Fa...

Page 10: ...PELIGRO GASES PELIGROSOS Las pinturas solventes insecticidas y otros materiales pueden ser perjudiciales si se inhalan o entran en contacto con el cuerpo Los gases pueden causar n usea desmayos o env...

Page 11: ...ancia posible del rea de pintado para salvaguardar contra la posibilidad de explosi n o incendio causado por partes el ctricas generando chispa 2 Prepare su pistola atomizadora para operaci n Consulte...

Page 12: ...orrespondinte NOTA El filtro de aire atomizado de dos etapas debe colorcarse en la lata de filtro marcada 2 Stage Filter con el lado verde hacia la turbina Despu s de varias limpiezas pudiera ser nece...

Page 13: ...os filtros 1 Limpie o reponga los filtros 1 Revise la fuente de poder 2 Revise y cambie el fusible 3 Mande cambiar los cepillos en un centro de servicio autorizado CAPSpray 1 Mande cambiar los cepillo...

Page 14: ...le voyant lumineux s allume c est qu il est temps d y voir Les filtres engorg s peuvent engendrer une surchauffe et peut tre endommager l unit Pour obtenir de plus amples renseignements en mati re de...

Page 15: ...42 0277475 Tubo del flujo de aire 1 43 0277337 Manguera de aire no se muestra 1 44 0275625 Accesorio de desconexi n r pida no se muestra 1 45 0524405 Manguera de aire del azote no se muestra 1 Article...

Page 16: ...garantie ne couvre pas les d fauts ou les dommages d coulant de l abrasion de la corrosion de l usage abusif de l emploi incorrect de n gligence d accidents de l usure normale d une installation fauti...