If troubleshooting steps are followed and the system still does not function, please contact your local Spray Specialist
or call 1
-
800
-
95
-
SPRAY (1
-
800
-
957
-
7729).
If any system/component malfunctions occur,
shut off
the system immediately and perform the following steps:
•
Disconnect and lock out electrical power
•
Close any pneumatic shutoff valves and relieve the pressure
•
Identify and correct the malfunction before restarting the system
•
Check all pneumatic, hydraulic, and electrical connections
GENERAL TROUBLESHOOTING
1) System won
’
t power on
•
Be sure disconnect is on
•
Measure power input at the disconnect
•
Check fuses
2) System does not spray or has a bad pattern
•
Check power to the system control panel
•
Check HV cable connection between the system control panel and the manifold
•
Verify trigger signal
•
Check manifold for clogging
3) Air in liquid line/poor pump performance
•
Check for leaks
•
Clean filter, check if clogged
4) No fluid at spray nozzles
•
Check for leaks
•
Clean filter, check if clogged
SECTION 8
TROUBLESHOOTING
Arc Fault Detection Tips
Cause:
Solution:
Arc occurring at the Electrostatic
Manifold nozzle
•
Ensure no air pockets are entrapped in the nozzles
•
Check that the Manifold isn
’
t too close to the target
•
Check for any grounded objects, other than the target, that may
be too close to the Manifold
•
Verify the silicone boots are tightly connected to the Manifold
electrode connection
Stack Light Quick
Reference Table
Light
Description
Flashing Red
Critical Fault
Solid Red
Standard Fault
Amber
System Not Ready
Solid Green
System Ready
Flashing Green
System Operating