GROUND WIRE
The ground wire assembly should come connected to the ground rods with 7/16 hex head bolts on each end of the
conveyor nozzle assembly. The ground wire assembly should be connected directly to an earth ground as defined by
local electrical codes.
6.4 CONTROL FUNCTIONS
VARIABLE ELECTROSTATIC FIELD
The nozzle bodies can be slid up and down inside the end blocks by loosening the 4 plastic thumb screws on both
ends of the assembly. This allows for minor adjustments toward and away from the target, and to increase or de-
crease the effects from the ground rods on the electrostatic field. The ground rods themselves can also be moved in-
ward to increase the effect.
ELECTROSTATIC VOLTAGE
The ES2500 Manifold is rated to work with a voltage from 0
-
30,000V. This wide range ensures that a variety of fluids
will achieve atomization and allow for adjustment for spray pattern and drop size.
WARNING: DO NOT exceed voltage rating for manifold nozzle assembly; serious injury or death may
occur.
MANIFOLD SECTIONS
Fluid is fed in through the push
-
to
-
connect fitting directly in the
center of each manifold section.
The ES2500 Manifold is available in
6”, 12”,
and
24”
long sec-
tions. These sections can be used individually, or combined, to
create a size that matches the desired spray coverage area.
Examples of possible Manifold configurations.