background image

mini LW

mini LW

5

DESCRIPTION OF THE LUMINAIRE

Please refer to the pictures on page 2:

① 

  Suspension yoke

  Knob for opening lamp cover

  Accessory retaining clip

  Accessory guides

⑤ 

Knob for focus and light beam adjustment

⑥ 

Handle for tilt regulation

INTRODUCTION

The luminaire you have bought conforms to 73/23/EEC,
EN 60598-1 and EN 60598-2-1 directives and 
regulations.
The labels on the side of the luminaire list the following 
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• protection index IP
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C 
• minimum distance from flammable surface
• information to find the position 0° of the luminaire: 

when the tip of the arrow points upwards 

• maximum tilt angle range. These limits, imposed by 

the lamp manufacturer, should not be exceeded as 
they would reduce the luminaire’s useful life or lead 
to its deterioration.

INSTALLATION

• The luminaires are intended for professional use only 

so they have to be installed and used by qualified 
technicians.

• The products are intended for indoor use: 

consequently they have to be protected from humidity 
and rain, if used in different conditions (IP 20)

• Do not mount the luminaire on or near a flammable 

surface

• Please note carefully the notes written on the labels 

of the luminaires.

• Do not forget to connect a safety rope, if required by 

local country safety regulations

• The luminaires can be either suspended, or mounted 

on a stand, by turning the yoke upside-down.

ELECTRICAL CONNECTIONS

Your luminaires have been designed to use low voltage 
150W-24V halogen lamps.
• The 

MI FN LW/CT

 e 

MI PC LW/CT

 models have an 

internal transformer and can be connected to a 220-
240V, 50-60 Hz mains power supply. The power cable 
conforms to CEI regulations 20-35.

• The 

MI FN LW

 and 

MI PC LW

 models requires 

the use of an external  transformer; please check 
it is a “safety CE tranformer” with input voltage 
corresponding to the mains one, output voltage not 
over 24V, continuous wattage at least 150W, and the 
minimum size of the wires between the transformer 
and the luminaire is 1,5 mm2 or more according to 
the distance  from the transformer.
Please refer to the relevant transformer instructions 
about the electrical wiring and the earth of the 
system.

Before and during the installation, follow the 
instructions below:
• Always check the earth wiring for the line being used.
• Ensure the required voltage of the unit is the same 

as the mains one for the models with internal 
transformer.

• Do not use lamps other than indicated on the lamp 

table (24V 150W max).

• There are no fuses inside the units, if it is necessary  

they should be installed in the mains

• The luminaires 

can be connected to a dimmer on 

the following conditions:

-  for  external  transformer models  (MI FN LW  e 

MI PC LW) check if the used transformer can 
work with     the dimmer and that the dimmer 
can work with the chosen transformer.

-  for  the  models  with internal  transformer  

(MI FN LW/CT and MI PC LW/CT) please check 
just that the used dimmer is suitable to deal with 
charges with transformers.

WARNING: replace immediately the lamp 

and/or the lenses if visibly damaged, 

even if still working.

WARNING: The luminaires MI FN LW/CT e MI 

PC LW/CT must always be earthed

Summary of Contents for mini Fresnel LW

Page 1: ...Manuale utente User manual cod MI FN LW MI FN LW CT MI PC LW MI PC LW CT mini Fresnel LW mini PC LW MI FN LW CT MI FN LW MI PC LW CT MI PC LW...

Page 2: ...be responsible for damage resulting from instructions not being followed 1 2 4 3 5 6 Accessori Accessories Codice Code Telaio porta gelatina Colour filter frame TC MINI Paraluce 4 alette 4 leaf barndo...

Page 3: ...i con trasformatori DESCRIZIONE DEL PROIETTORE Riferendoci alle immagini di pag 2 Staffa di sospensione Pomello per apertura vano portalampada Gancio di ritegno accessori Guide porta accessori Pomello...

Page 4: ...ampada per regolare la messa a fuoco e l ampiezza del fascio luminoso PULIZIA Per una maggiore resa del faro occorre tener puliti il pi possibile la lente e lo specchio Per fare questo Scollegare il f...

Page 5: ...naires have been designed to use low voltage 150W 24V halogen lamps The MI FN LW CT e MI PC LW CT models have an internal transformer and can be connected to a 220 240V 50 60 Hz mains power supply The...

Page 6: ...is possible to advance or retreat the lamp holder to adjust the focus and the light beam CLEANING For the best results it is important to ensure that both the lens and the reflector are kept clean To...

Page 7: ...weights Modello Model Modell Mod le V W Codice Code lm t h K MI FN LW MI PC LW MI FN LW CT MI PC LW CT G 6 35 24 150 A1 216 5200 50 3400 24 150 JC 20H 3000 2000 3000 Lampade Lamps MI FN LW Kg 1 3 MI F...

Page 8: ...tlight s r l Via Sardegna 3 20098 S Giuliano Milanese Milano Italy Tel 39 02 98830 1 Fax 39 02 98830 22 E mai info spotlight it www spotlight it certified quality management system ISO 9001 2008 mini...

Reviews: