RANGES & SPECIFIC

A

TIONS

TIME

• AM, PM, hour

, minute, second

• 12/24 hour format

• Calendar: month, date, day display with auto

 

leap year adjustment

• Dual T

ime Zone

ALARM

• Daily alarm

• Alarm duration: 30 seconds

CHRONOGRAPH

• Resolution: 1/100 second

• Measuring range: 23 hours, 59 minutes,

 

59.99 seconds

• 100 Lap

• Split times display

HEART RA

TE

• Range: 30-240 beats per minute

• 4 Heart Rate T

arget Zones

• Calorie T

racking Range: 0-9999

• Fat Burn range: 0 - 1296g

COUNTDOWN TIMER

• Resolution: 1 second

• Measuring Range: 23 hours, 59 minutes,

 

59 seconds

OTHER

• Electroluminescent (EL) backlight

• W

ater resistant up to 50 meters

 

• Battery: CR 2032 (X2)

FCC C

OMPLIANCE

This equipment has been tested and found to comply with the limits for a Class B digital device,

 

pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a

 

residential installation. This equipment generates, uses and can radiate radio frequency energy and,

 

if not installed and used in accordance with the instructions, may cause harmful interference to

 

radio communications. However

, there is no guarantee that interference will not occur in a particular

 

installation.  If this equipment does cause harmful interference to radio or television reception, which

 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the

 

interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the transmitting equipment and receiver

.

• 

Connect the receiver appliance into an outlet on a circuit different from the location that to which

 

the transmitting watch is being used.

• 

Consult the dealer or an experienced radio technician for help.

: Changes or modifications not expressly approved by the party responsible for compliance could void

 

the user’

s authority to operate the product.

when pr

inting out or making PDF – PRINT A

T

 1

45%                    

fi 

nal siz

e per panel 4 x 5.45

S

P

4

9

6

1

IS

0

1

R

O

D

R

A

.i

n

d

d

  

 2

9

-3

0

SP4961IS01RODRA.indd   29-30

1

0

/1

5

/1

0

  

 1

0

:3

4

 A

M

10/15/10   10:34 AM

Summary of Contents for DUO 1025

Page 1: ...DUO 1025 DUAL USE HEART RATE MONITOR DUO 1025 when printing out or making PDF PRINT AT 145 nal size per panel 4 x 5 45 SP4961IS01RODRA indd 1 SP4961IS01RODRA indd 1 10 15 10 10 34 AM 10 15 10 10 34 AM...

Page 2: ...NG THE WATCH DISPLAY ICONS AND THEIR MEANINGS 17 OPERATING HEART RATE EXERCISE TIMER MODE 18 INTELLITRACK HEART RATE VISUAL DISPLAY 19 HEART RATE EXERCISE MEMORY 20 OPERATING THE CHRONOGRAPH 21 VIEWIN...

Page 3: ...Down mode PRESS HOLD ANY KEY for 3 seconds see page 10 for more information on Power Down mode WARNING Before starting any exercise program or performing any vigorous physical activity we strongly su...

Page 4: ...OMER SUPPORT If you experience any problems with this product or have questions please first contact our Customer Service Team at 1 866 694 4575 We are ready to help WATCH FUNCTIONS TIME Time Day Date...

Page 5: ...ing sequence PRESS HOLD Reset Exercise Timer Chronograph LAP VIEW L V Decrease setting values being adjusted in programming sequence Start new Lap in Chronograph mode Reset Countdown Timer Scroll thro...

Page 6: ...itter provides constant heart rate information throughout the duration of your workout To ensure a proper heart rate display the chest transmitter must be properly adjusted Snap the plastic tabs at th...

Page 7: ...nit when the monitor is not being used for long periods of time To activate Power Down mode 1 In Time mode PRESS HOLD the START STOP MODE keys for 5 seconds Note Time Date User Profiles and Memory fil...

Page 8: ...G THE WATCH FUNCTIONS SETTING USER PROFILE The Sportline Duo 1025 uses an advanced algorithm based on your User Profile to estimate your maximum heart rate and calculate other heart rate information T...

Page 9: ...at and carbohydrates Cardiovascular strengthening increased metabolism and elevated caloric burn are the primary benefits SETTING HEART RATE TARGET ZONES continued The Sportline Duo 1025 automatically...

Page 10: ...urn to Time mode 5 Turn Alarm ON or Off by PRESSING the START STOP S S key ADJUST S S or L V SET MODE SETTING DUAL TIME ZONE To set Dual Time 1 In Dual Time mode PRESS HOLD the MODE SET MODE key to en...

Page 11: ...perate the Exercise Timer in Heart Rate Exercise Timer mode 1 To START timing PRESS the START STOP S S key 2 To STOP timing PRESS the S S key 3 Scroll through time IN ABOVE and BELOW Target Heart Rate...

Page 12: ...F TARGET ZONE HEART RATE EXERCISE MEMORY The Sportline Duo 1025 has a Memory mode that allows you to view detailed feedback from your last 7 workouts NOTE Workouts are saved most recent Work 1 to olde...

Page 13: ...Sportline Duo 1025 has a Chronograph Memory that recalls information from your previous workout Note To view Chronograph Memory do not reset the Chronograph To view Chronograph Memory 1 With the Chron...

Page 14: ...OUNTDOWN TIMER The Sportline Duo 1025 is equipped with a 24 hour Countdown Timer To set Timer 1 PRESS HOLD the MODE SET MODE key in Timer mode 2 Adjust Hours by PRESSING START STOP S S or LAP VIEW L V...

Page 15: ...fresh battery To replace the battery 1 Using a coin turn the battery door counter clockwise until the door comes free of the watch 2 Take care not to damage the O ring seal for the battery compartment...

Page 16: ...ical products and batteries contain trace elements including Mercury Hg Cadmium Cd and Lead Pb which could be harmful to our environment and therefore our health We must all be careful to dispose of t...

Page 17: ...rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee...

Page 18: ...signed manufactured and packaged If any parts are missing or damaged please contact us at the address above and we will replace the unit at no charge Guarantee does not cover crystal or battery 2009 D...

Page 19: ...10701 Distributed in the UK by EB Brands UK Worcester WR4 9FA All Rights Reserved 2010 SP4961IS01RODRA DUO 1025 DUAL USE HEART RATE MONITOR when printing out or making PDF PRINT AT 145 nal size per pa...

Reviews: