background image

4

Cabulator

IN  THIS  MANUAL  A  LIGHTNING  SYMBOL  WITHIN  A  TRIANGLE  WARNS  YOU  ABOUT  THE 
POTENTIAL FOR DANGEROUS ELECTRICAL SHOCKS – WHICH CAN ALSO OCCUR EVEN AFTER 
THE MACHINE HAS BEEN DISCONNECTED FROM A POWER SOURCE.

AN  EXCLAMATION  MARK  (!)  WITHIN  A  TRIANGLE  IS  INTENDED  TO  MAKE  YOU  AWARE  OF 
IMPORTANT  OPERATIONAL  ADVICE  AND/OR  WARNINGS  THAT  MUST  BE  FOLLOWED.  BE 
ESPECIALLY ATTENTIVE TO THESE AND ALWAYS FOLLOW THE ADVICE THEY GIVE.

The symbol of a lamp directs your attention to explanations of important functions or applica-
tions.

Attention:

 Do not attempt any alterations to this machine without the approval or supervision 

of SPL electronics GmbH. Doing so could nullify completely any and all of your warranty/guar-
antee rights and claims to user support.

The scope of delivery comprises the Cabulator, the external power supply, the guarantee card 
and this manual. 

Please  keep  the  original  packaging.  In  case  of  a  service  procedure  the  original  packaging 
ensures a safe transport. It also serves as a safe packaging for your own transports if you do 
not use special transportation cases.

Please note and retain this manual. Carefully read and follow all of the safety and operating 
instructions before you use the machine. Be doubly careful to follow all warnings and special 
safety instructions noted in this manual and on the unit. 

Connections: 

Only use the connections as described. Other connections can lead to health 

risks and equipment damage.

Water and humidity:

 Do not use this machine anywhere near water (for example near a wash 

basin or bath, in a damp cellar, near swimming pools, or the like). In such cases there is an 
extremely high risk of fatal electrical shocks!

Insertion  of  foreign  objects  or  fluids: 

Never  allow  a  foreign  object  through  any  of  the 

machine‘s  chassis  openings.  You  can  easily  come  into  contact  with  dangerous  voltage  or 
cause a damaging short circuit. Never allow any fluids to be spilled or sprayed on the machine. 
Such actions can lead to dangerous electrical shocks or fire! 

Opening the unit:

 Do not open the machine housing, as there is great risk you will damage the 

machine, or – even after being disconnected – you may receive a dangerous electrical shock!

Electrical power:

 Run this machine only from sources which can provide proper power at the 

prescribed rating. When in doubt about a source, contact your dealer or a professional elec-
trician. To be sure you have isolated the machine, do so by disconnecting the power cord from 
your wall connection. Be sure that the power cord plug is always accessible. When not using 
the machine for a longer period, make sure to unplug it from your wall power socket.  

Cord  protection:

  Make  sure  that  your  power  and  signal  cords  are  arranged  to  avoid  being 

stepped on or any kind of crimping and damage related to such event. Do not allow any equip-
ment or furniture to crimp the cords.

Power  connection  overloads: 

Avoid  any  kind  of  overload  in  connections  to  wall  sockets, 

extension or splitter power cords, or to signal inputs. Always keep manufacturer warnings 
and instructions in mind. Overloads create fire hazards and risk of dangerous shocks!           >

Symbols and Notes

Scope of Delivery & Packaging

Important Security Information

Summary of Contents for Cabulator 2930

Page 1: ...Manual Power soak speaker simulator and D I output for guitar amplifiers Cabulator Model 2930...

Page 2: ...0 2163 983 420 E Mail info spl info Internet www spl info The construction of the Cabulator Model 2930 is in compliance with the stan dards and regulations of the European Cummunity Notes on Environm...

Page 3: ...Overview Wiring Examples 9 Rear Panel Connections 10 Speaker In Important Warning on Connecting Guitar Amps Soak Output 10 D I Output DC Power On and Off Power Connection Passive Power Soak 11 FRONT...

Page 4: ...where near water for example near a wash basin or bath in a damp cellar near swimming pools or the like In such cases there is an extremely high risk of fatal electrical shocks Insertion of foreign ob...

Page 5: ...sure that any service technician uses original replacement parts or those with identical specifications as the originals Incorrectly substituted parts can lead to fire electrical shock or other dange...

Page 6: ...quipment in the professional music film multimedia and broadcasting industries Our products enjoy a first rank worldwide reputation for innovation user friendli ness and consistently superior performa...

Page 7: ...gnals for live mixes are at recording quality level and free from crosstalk from other sound sources The guitarist can play in the control room to listen and react to the playback directly Significant...

Page 8: ...xternal power supply with the following specifications 9 volts DC regulated power supply 200mA minimum DC jack connector 2 1mm outer plus center minus Boss standard On and Off The Cabulator has no sep...

Page 9: ...L NUMBER 8 Load Only Connect to Speaker Out of Amplifier Max 100 Watts Tip Sleeve GND SOAK OUTPUT SOAK OUTPUT Power Soak Output Tip Sleeve GND Connect to Speaker Cabinet 4 to 16 Load Transformer Bal L...

Page 10: ...mplifiers rated at a 100W maximum to maintain a further 100W reserve for signal peaks A guitar amp may be used ONLY within its normal operating parameters The Cabulator may be loaded up to 200W But pl...

Page 11: ...r unplug the external power supply in order to switch the unit on or off First connect the DC connector before you plug in the power connector Always keep the DC connector plugged when you power the u...

Page 12: ...nt from the sound simulation unit There is no mutual interac tion which would complicate operation 3 The power soak functionality and regulation is a passive design can also be used without power conn...

Page 13: ...ain SPEAKER VOICING setting and do not want to change this sound result you have to adjust the signal levels at following units AD converters line inputs of a console etc Usually the ranges to set the...

Page 14: ...onnect to Recording Device Stagebox etc D I OUTPUT D I OUTPUT DC POWER DC POWER The Tonehunter logo is a registered trademark of Tonehunter Ltd MADE IN GERMANY IN ORDER TO AVOID POSSIBLE DAMAGE OF YOU...

Page 15: ...I OUTPUT DC POWER DC POWER The Tonehunter logo is a registered trademark of Tonehunter Ltd MADE IN GERMANY IN ORDER TO AVOID POSSIBLE DAMAGE OF YOUR GUITAR AMPLIFIER DO NOT SET ITS MASTER VOLUME ABOV...

Page 16: ...er supply for voltages from 100 250 volts 9V DC 200 mA 2 1 mm DC plug Power consumption 0 5VA Fuse internal 100 250 V AC T 100 mA Dimensions Weight Height x width x depth 134 mm x 300 mm x 207 mm Weig...

Page 17: ...Cabulator Model 2930 Block Diagram...

Page 18: ...Copy Master Recall Settings Guitarist Album Gig Title Engineer Track s Groups Date...

Page 19: ...19 Cabulator Your Notes...

Page 20: ...20 Cabulator Manual Cabulator...

Reviews: