background image

9

Cabulator

Rear Panel

 Overview, Wiring Examples

Guitar amplifier

Cabinet

Pow

er

cable

USE SPE

AKER C

ABL
E

USE SPE

AKER C

ABL
E

You can use balanced or unbalanced 

TRS connections with the D. I. OUTPU

T. 

Please 

pay attention to fur

ther advices on sockets and switches on the follo

wing

 p

ages as well as the security advices on 

pages 4 and 5.

P. A. 

(F

.O.H./monitoring)

AD conv

er

ter

(Interface/D

AW
)

or

SPE
AKER IN

SPE

AKER IN

De

ve

loped by 

Tonehunte

r, Germany

www

.tonehunter

.co
m

SERIAL

 NUMBER

8Ω

Lo

ad Only 

!

Connect to S

peaker

Out of Amplifier

Max:

 

100
 

W

atts 

T

ip 

= (+)/

Sleev

= GND

SOAK OUTPUT

 SOAK OUTPUT

Pow

er Soak

Outpu

t

T

ip 

= (+)/

Sleev

= GND

Connect to

 

Speaker Cabinet

4

Ω to

 

16

Ω 

Lo

ad

Transformer Bal.

Line Output

T

ip

 

= (+)/ 

R

ing = 

(–)

Sleev

Audio GND Only!

DC 9V

Connect to 

R

ecording Device,

Stagebo

x, etc.

D.I. OUTPUT

 D.I. OUTPUT

DC POWE

R

D

P

O

W

ER

+

® 

The 
To

nehunter logo is a registered 

trademark of 

To

nehunter Ltd

.

M

A

D

E I

N

 G

ER

M

A

N

Y

IN ORDER 

TO

 AV

OID POSSIB

LE

 DA
MAGE OF 

YOUR GUIT

AR AMPLIFIER DO NO

SE

IT

MA
STER 

VOL
UME ABO

VE

 

70%

.

REFER 

TO

 MANU

AL

 FOR MORE INFORM

AT

ION.

IM

P

O

R

TA

N

T A

D

V

IC

E

Sound Performance La

b

www

.spl.info

® 

The SP

L logo is a registered 

trademark of SP

L electronics Gmb

H

Summary of Contents for Cabulator 2930

Page 1: ...Manual Power soak speaker simulator and D I output for guitar amplifiers Cabulator Model 2930...

Page 2: ...0 2163 983 420 E Mail info spl info Internet www spl info The construction of the Cabulator Model 2930 is in compliance with the stan dards and regulations of the European Cummunity Notes on Environm...

Page 3: ...Overview Wiring Examples 9 Rear Panel Connections 10 Speaker In Important Warning on Connecting Guitar Amps Soak Output 10 D I Output DC Power On and Off Power Connection Passive Power Soak 11 FRONT...

Page 4: ...where near water for example near a wash basin or bath in a damp cellar near swimming pools or the like In such cases there is an extremely high risk of fatal electrical shocks Insertion of foreign ob...

Page 5: ...sure that any service technician uses original replacement parts or those with identical specifications as the originals Incorrectly substituted parts can lead to fire electrical shock or other dange...

Page 6: ...quipment in the professional music film multimedia and broadcasting industries Our products enjoy a first rank worldwide reputation for innovation user friendli ness and consistently superior performa...

Page 7: ...gnals for live mixes are at recording quality level and free from crosstalk from other sound sources The guitarist can play in the control room to listen and react to the playback directly Significant...

Page 8: ...xternal power supply with the following specifications 9 volts DC regulated power supply 200mA minimum DC jack connector 2 1mm outer plus center minus Boss standard On and Off The Cabulator has no sep...

Page 9: ...L NUMBER 8 Load Only Connect to Speaker Out of Amplifier Max 100 Watts Tip Sleeve GND SOAK OUTPUT SOAK OUTPUT Power Soak Output Tip Sleeve GND Connect to Speaker Cabinet 4 to 16 Load Transformer Bal L...

Page 10: ...mplifiers rated at a 100W maximum to maintain a further 100W reserve for signal peaks A guitar amp may be used ONLY within its normal operating parameters The Cabulator may be loaded up to 200W But pl...

Page 11: ...r unplug the external power supply in order to switch the unit on or off First connect the DC connector before you plug in the power connector Always keep the DC connector plugged when you power the u...

Page 12: ...nt from the sound simulation unit There is no mutual interac tion which would complicate operation 3 The power soak functionality and regulation is a passive design can also be used without power conn...

Page 13: ...ain SPEAKER VOICING setting and do not want to change this sound result you have to adjust the signal levels at following units AD converters line inputs of a console etc Usually the ranges to set the...

Page 14: ...onnect to Recording Device Stagebox etc D I OUTPUT D I OUTPUT DC POWER DC POWER The Tonehunter logo is a registered trademark of Tonehunter Ltd MADE IN GERMANY IN ORDER TO AVOID POSSIBLE DAMAGE OF YOU...

Page 15: ...I OUTPUT DC POWER DC POWER The Tonehunter logo is a registered trademark of Tonehunter Ltd MADE IN GERMANY IN ORDER TO AVOID POSSIBLE DAMAGE OF YOUR GUITAR AMPLIFIER DO NOT SET ITS MASTER VOLUME ABOV...

Page 16: ...er supply for voltages from 100 250 volts 9V DC 200 mA 2 1 mm DC plug Power consumption 0 5VA Fuse internal 100 250 V AC T 100 mA Dimensions Weight Height x width x depth 134 mm x 300 mm x 207 mm Weig...

Page 17: ...Cabulator Model 2930 Block Diagram...

Page 18: ...Copy Master Recall Settings Guitarist Album Gig Title Engineer Track s Groups Date...

Page 19: ...19 Cabulator Your Notes...

Page 20: ...20 Cabulator Manual Cabulator...

Reviews: