12. ASSEMBLY OF HIGH PRESSURE HOSE WITH THE UNIT
Connect the quick release high pressure hose to the outlet connector of the unit.
13. WATER INLET CONNECTION
Connection to potable water mains can be achieved by using a general garden hose set (1/2 inch
diameter).
Connect the water supply hose to the water inlet connection. In case of poor water quality the use of
an external water filter is recommended. Contact your Spitwater agent for advice and /or supply.
Make sure the water supply temperature and pressure meet the values specified in the technical data,
then turn the water supply on. Visually check for leaks and contact your Spitwater service agent if
found.
Open the water supply and fill the water tank. The float valve will automatically stop the water flow
when the water tank is full.
Water that has flowed through backflow preventer is considered to be non-potable (non-drinkable).
For suction supply / non-pressure water supply, other than potable water mains, contact your
authorized Spitwater service agent for advice.
High pressure hoses, fittings and
couplings are important for the
safety of the machine. Use only high
pressure hoses, couplings and
fittings recommended by Spitwater.
Do not pull on high pressure hose in
order to move the unit.
WARNING:
This high pressure cleaner is only
allowed to be connected with the
drinking water mains, when an
appropriate backflow preventer has
been installed, AS/NZS 60335.2.79.
Follow all local standards and regulations
applicable to water connection.